Laserfiche WebLink
+ 1997 UNIFORM BUILDING CODE 106.2 <br /> 106.4.1 <br /> 9. Temporary motion picture,television and theater.stage sets Plans for buildings of other than Group R,Division 3 and Group ' <br /> and scenery. U Occupancies shall indicate how required structural and fire- <br /> 10. Window awnings supported by an exterior wall of Group R, resistive integrity will be maintained where penetrations will be <br /> Division 3,and Group U Occupancies when projecting not more made for electrical, mechanical, plumbing and communication <br /> conduits,pipes and similar systems. <br /> than 54 inches(1372 mm). <br /> 11. Prefabricated swimming pools accessory to a Group R,Di- 1063.4 Architect or engineer of record. <br /> vision 3 Occupancy in which the pool walls are entirely above the 1063.4.1 General. When it is required that documents be pre- <br /> adjacent grade and if the capacity does not exceed 5,000 gallons pared by an architect or engineer,the building official may require <br /> (18 927 L). the owner to engage and des-igp ate on the building permit applica- <br /> Unless otherwise exempted,separate plumbing,electrical and tion an architect or engineer Ao shall act as the architect or engi- <br /> mechanical permits will be required for the above-exempted neer of record. If the circumstances require, the owner may <br /> items. designate a substitute architect or engineer of record who shall <br /> perform all of the duties requited of the original architect or engi- <br /> Exemption from the permit requirements of this code shall not neer of record.The building official shall be notified in writing by <br /> be deemed to grant authorization for any work to be done in any the owner if the architect or engineer of record is changed or is un- <br /> manner in violation of the provisions of this code or any other laws able to continue to perform the duties. <br /> or ordinances of this jurisdiction. The architect or engineer of record shall be responsible for re- <br /> 1063 Application for Permit. viewing and coordinating all submittal documents prepared by <br /> others,including deferred submittal items,for compatibility with <br /> 1063.1 Application. To obtain a permit,the applicant shall first the design of the building. <br /> file an application therefor in writing on a form furnished by the 106.3.4.2 Deferred submittals. For the purposes of this section, <br /> code enforcement agency for that purpose.Every such application deferred submittals are defined as those portions of the design that <br /> shall: are not submitted at the time of the application and that are to be <br /> 1. Identify and describe the work to be covered by the permit submitted to the building official within a specified period. <br /> for which application is made. Deferral of any submittal items shall have prior approval of the <br /> 2. Describe the land on which the proposed work is to be done building official.The architect or engineer of record shall list the <br /> by legal description,street address or similar description that will deferred submittals on the plans and shall submit the deferred sub- <br /> readily identify and definitely locate the proposed building or mittal documents for review by the building official. <br /> work. Submittal documents for deferred submittal items shall be sub- <br /> 3. Indicate the use or occupancy for which the proposed work is mitted to the architect or engineer of record who shall review them <br /> intended. and forward them to the building official with a notation indicat- <br /> ing that the deferred submittal documents have been reviewed and <br /> 4. Be accompanied by plans, diagrams, computations and that they have been found to be in general conformance with the <br /> specifications and other data as required in Section 106.3.2. design of the building.The deferred submittal items shall not be <br /> 5. State the valuation of any new building or structure or any installed until their design and submittal documents have been ap- <br /> addition,remodeling or alteration to an existing building. proved by the building official. <br /> 6. Be signed by the applicant, or the applicant's authorized 106.3.5 Inspection and observation program. When special <br /> agent. inspection is required by Section 1701,the architect or engineer of <br /> 7.Give such other data and information as may be required by record shall prepare an inspection program that shall be submitted <br /> the building official. to the building <br /> g official for approval prior to issuance of the build- <br /> ing permit.The inspection program shall designate the portions of <br /> 1063.2 Submittal documents. Plans,specifications,engineer- the work that require special inspection and the name or names of <br /> ing calculations, diagrams,soil investigation reports,special in- the individuals or firms who are to perform the special inspec- <br /> spection and structural observation programs and other data shall tions,and indicate the duties of the special inspectors. <br /> constitute the submittal documents and shall be submitted in one The special inspector shall be employed by the owner,the engi- <br /> or more sets with each application for a permit.When such plans neer or architect of record,or an agent of the owner,but not the <br /> are not prepared by an architect or engineer,the building official contractor or any other person responsible for the work. <br /> may require the applicant submitting such plans or other data to When structural observation is required by Section 1702,the in- <br /> demonstrate that state law does not require that the plans be pre- spection program shall name the individuals or firms who are to <br /> pared by a licensed architect or engineer. The building official perform structural observation and describe the stages of <br /> may require plans,computations and specifications to be prepared construction at which structural observation is to occur. <br /> and designed by an engineer or architect licensed by the state to <br /> The inspection program shall include samples of inspection re- <br /> practice as such even if not required by state law. <br /> ports and provide time limits for submission of reports. <br /> EXCEPTION:The building official may waive the submission of <br /> plans, calculations, construction inspection requirements and other 106.4 Permits Issuance. <br /> data if it is found that the nature of the work applied for is such that re- <br /> viewing of plans is not necessary to obtain compliance with this code. 106.4.1 Issuance. The application, plans, specifications, com- <br /> putations and other data filed by an applicant for a permit shall be <br /> 106.33 Information on plans and specifications. Plans and reviewed by the building official.Such plans may be reviewed by <br /> specifications shall be drawn to scale upon substantial paper or other departments of this jurisdiction to verify compliance with <br /> cloth and shall be of sufficient clarity to indicate the location,na- any applicable laws under their jurisdiction.If the building official <br /> ture and extent of the work proposed and show in detail that it will finds that the work described in an application for a permit and the <br /> conform to the provisions of this code and all relevant laws,ordi- plans,specifications and other data filed therewith conform to the <br /> nances,rules and regulations. requirements of this code and other pertinent laws and ordinances, <br /> 1-3 <br />