Laserfiche WebLink
t <br /> TABLE NO.5-A—WALL AND OPENING PROTECTION OF OCCUPANCIES BASED ON LOCATION ON PROPERTY ,fOo <br /> TYPES Ii ONE-HOUR,II-N AND V CONSTRUCTION:For exterior wall and opening protection of Types II One-hour,II-N and V <br /> buildings,see table below and Sections 504,709,1903 and 2203. Z <br /> This table does not apply to Types I,II-F.R.,III and IV construction,see Sections 1803,1903,2003 and 2103. T <br /> FIRE RESISTANCE OF OPENINGS IN O <br /> GROUP DESCRIPTION OF OCCUPANCYEXTERIOR WALLS EXTERIOR WALLS1 <br /> 1—Any assembly building or portion of a building with a legitimate stage <br /> and an occupant load of 1,000 or more Not applicable(See Sections 602 and 603) C <br /> r- <br /> 2—Any building or portion of a building having an assembly room with an pZ <br /> A occupant load of less than 1,11110 and a legitimate stage 2 hours less than 10 Not permitted less than 0 <br /> See also _.I—Any building or portion of a building having an assembly room with an 5 feet n <br /> 1 hour less than O <br /> qp fee <br /> Section • occupant load of 300 or more without a legitimate stage,including such feet, t Protected less than G <br /> 602 buildings used for educational purposes and not classed as a Group E or tofeet m <br /> Group B.Division 2 Occupancy <br /> 3—Any building or portion of a building having an assembly room with an Not permitted less than <br /> occupant load of less than 300 without a stage,including such buildings 2 hours less than 5 feet, 5 feet <br /> used for educational purposes and not classed as a Group E or Group B. 1 hour less than 20 feett Protected less than <br /> Division 2 Occupancy "k' 10 feet <br /> 4—Stadiums,reviewing stands and amusement park structures not included Protected less than <br /> within other Group A Occupancies I hour less than 10 feet 10 feet <br /> I—Repair garages where work is limited to exchange of pans and <br /> maintenance requiring no open(lame,welding,or use of Class 1,11 or <br /> 111-A liquids <br /> H 2—Drinking and dining establishments having an occupant load of less than Not permitted less than <br /> See also 50,wholesale and retail stores,office buildings,printing plants,police 5 feet <br /> Section and fire stations,factories and workshops using material not highly I hour less than 20 feet Protected less than <br /> 702 flammable or com6usriMe storage and sales rooms for combusts 10 feet <br /> goods,paint stores wit out bulk handling <br /> Buildings or portions of buildings having rooms used for educational <br /> purposes,beyond the 12th grade,with less than 50 occupants in any room <br /> rr <br /> N (Continued) > <br />