My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016 - 00962 - mound septic system
Orono
>
Property Files
>
Street Address
>
W
>
White Oak Circle
>
2775 White Oak Circle - 04-117-23-42-0015
>
Septic
>
2016 - 00962 - mound septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:14:01 PM
Creation date
2/3/2020 1:01:01 PM
Metadata
Fields
Template:
x Address Old
House Number
2775
Street Name
White Oak
Street Type
Circle
Address
2775 White Oak Cir
Document Type
Septic
PIN
0411723420015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br /> 2250 gallon Septic tank (minimum) Tank options: none <br /> %Po urger eani wren rnuurpre comp/eanrca <br /> 1000 gallon Dose tank (minimum) at 25.00 gpi <br /> 38 GPM @ 19 ft. of head, Pump required <br /> 6.8 inch swing on Demand float which translates to roughly 4.4 inches of float tether length <br /> if time dosing is required --> 4.4 minutes ON time & 9 hours OFF time <br /> 19 inches from bottom of tank to"pump ON"float, or 12 inches to"timer ON"float <br /> 22 inches from bottom of tank to"Hi Level Alarm"or 32 inches to"Hi level alarm" if time dosed <br /> 113 ft. of 2.0 inch supply tine with end feed manifold connection <br /> (Tip: "top feed"manifold to control drainback) <br /> 20 inch, or 1.7 ft. Sand Lift Mound <br /> 10.0 ft. wide by 50.0 ft. long Rock bed <br /> 3 laterals 2.00 inch diameter 48.0 ft. long 3.0 ft. lateral spacing <br /> 1/4" inch perfs 3.0 ft. perforation spacing <br /> No Effluent fitter E alarm <br /> 3 clean out&valve box assemblies <br /> 27.0 ft.Total sand ABSORPTION width (minimum) <br /> 0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br /> 17.0 ft. Downslope (sang beyond rockbed. minimum,; <br /> Specific slope ratios give BERM widths (topsoil beyond rockbed)of: <br /> 4:1 upslope ratio 13 ft. upslope berm <br /> 4:1 sideslope 16 ft. sideslope berms <br /> 4:1 downslope 20 ft. downslope berm <br /> 4" inspection pipe <br /> 18" cover on top <br /> k Upstope berm 13 } Downslope berm 20 <br /> +C ) <br /> 12" cover on sides <br /> �_ _ (6"loamy cap&6"topsoil) <br /> 1.7 Clean sand lift <br /> 1.3 -..-' i <br /> 1 <br /> Absorption Width 27.0 <br /> Note: <br /> For 0 to 1%slopes, Absorption Width is measured from the Bed equally in both directions. <br /> For slopes >1%, Absorption Width is measured downhill from the upslope edge of the Bed <br /> Rock Bed: 17.0 yd3 or*1.4= 24 ton 6 inches under pipe <br /> Mound Sand: 163 yd3 or*1.4= 229 ton calculation based on 3:1/4:1 slope from top of rockbe <br /> Loamy Cap: 68 yd3 or*1.4= 95 ton 6"deep <br /> Topsoil: 79 yd''or*1.4= 111 ton 6"deep <br />
The URL can be used to link to this page
Your browser does not support the video tag.