1995 - 006973 - new septic system
Orono
>
Property Files
>
Street Address
>
W
>
White Oak Circle
>
2760 White Oak Circle - 04-117-23-42-0018
>
Septic
>
1995 - 006973 - new septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:14:07 PM
Creation date
2/3/2020 12:33:07 PM
Metadata
Fields
Template:
x Address Old
House Number
2760
Street Name
White Oak
Street Type
Circle
Address
2760 White Oak Cir
Document Type
Septic
PIN
0411723420018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S-P ,TESTING, INC. Steven B. Schirmers — MPCA Cert. No. 627 <br /> 951 Katydid Lane NE • St. Michael, MN 55376 • (612) 497-3566 <br /> October 8, 1994 <br /> John Shannon <br /> 2760 White Oak Circle <br /> Orono, Henn. Co. , MN <br /> This On-Site Sewage Treatment System is Designed for a Type 1 , four <br /> bedroom home Designed in accordance with the Minnesota Pollution <br /> Control Agency Chapter 7080 and local ordinances . <br /> This site has an existing non-conforming system with the bottom <br /> of the system less than 3 ' from saturated soils (mottled soil ) . <br /> A Soil Boring into the existing system indicated the system <br /> is hydraulically overloaded. <br /> The soils on this site are a clay loam. A seasonally high water <br /> table was located at 22" & 24" , (mottled soil ) . Que to the <br /> seasonally high water table, a Pressurized Mound System will <br /> need to be installed. The bottom of the rock bed must be located <br /> at least 3 ' above the seasonally high water table . <br /> The existing tanks may be used upon approval by the local Inspector . <br /> The tanks must be water tight. Approval will be needed from the <br /> city to be 50 ' away from the stream. See site plan. <br /> The soils at a depth of 12" have a percolation rate averaging <br /> 10 . 8 min/inch. <br /> A pumping chamber will need to be installed to lift the effluent <br /> to the treatment area . <br /> The supply line will need to cross a stream. Recommend to install <br /> the supply line deep below the frost line but allow the manifold <br /> & approx. 75 ' of the supply line to have back drainage. A second <br /> option would be to exit the pumping chamber near the bottom of <br /> the tank approx. 18" above the bottom to allow total back drainage. <br /> The new exit from the tank must be properly sealed. <br /> The manifold and supply line pipe must have back drainage to the <br /> pumping chamber. The distribution pipes shall have their ends <br /> capped. Be sure the rock and sand fill material are clean. The <br /> sod layer below the entire mounded area must be turned over, just <br /> break up the sod , be sure not to over work. <br /> CONT ' D <br />