My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2001 - P03577 - mechanical
Orono
>
Property Files
>
Street Address
>
W
>
White Oak Circle
>
2760 White Oak Circle - 04-117-23-42-0018
>
Permits/Inspections
>
2001 - P03577 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:14:08 PM
Creation date
2/3/2020 12:08:47 PM
Metadata
Fields
Template:
x Address Old
House Number
2760
Street Name
White Oak
Street Type
Circle
Address
2760 White Oak Cir
Document Type
Permits/Inspections
PIN
0411723420018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
------ - - -------- <br /> RH <br /> VAC-Residential&Light Commercial HVAC Loads Program • Elite Software Development,Inc. <br /> Ditter,Inc. Stephenson/Shannon <br /> Hamel,MN 55340-9691 02-27-2001 Page 2 <br /> Total uilding Summary Loads <br /> Component Area Sen. Lat. Sen. Total <br /> Description Quan Loss Gain Gain Gain <br /> 3E Window Double Pane Low Emit TIM Frame 199 7,305 0 9,305 9,305 <br /> 8M Glass Door Double Clear Glass Wood Frame 105 5,322 0 5,775 5,775 <br /> 12H Wall R-19 + 1/2" Gypsum Board(R-0.5) 817 4,510 0 1,158 1,158 <br /> 16H Ceiling R-38 Insulation 425 1,017 0 486 486 <br /> 22D Slab on Grade 2" Edge Insulation(R-11) 59 1,140 0 0 0 <br /> Subtotals for structure: 1,605 19,294 0 16,724 16,724 <br /> Active People: 0 0 0 0 0 <br /> Inactive People: 0 0 0 0 0 <br /> Appliances: 0 0 0 0 0 <br /> Lighting: 0 0 0 <br /> Ductwork: 0 0 0 0 0 <br /> Infiltration: Winter CFM: 53.8, Summer CFM: 26.9 304 5,286 639 575 1,214 <br /> Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0 <br /> Sensible Gain Total: 17,— 299 <br /> Temperature Swing Multiplier: X1.00 <br /> B ----- --- ----- --uiing Load Totals: 24,580 639 17,299 17,938 <br /> Check Figures <br /> Total Building Supply CFM: 810 CFM per square foot: 0.953 <br /> Square feet of room area: 850 Square feet per ton: 454.015 <br /> ------ ---- ----- <br /> Building Loads <br /> Total heating required with outside air: 24,580 Btuh 24.580 MBH <br /> Total sensible gain: 17,299 Btuh 96 % <br /> Total latent gain: 639 Btuh 4 % <br /> Total cooling required with outside air: 17,938 Btuh 1.495 Tons (based on sensible + latent) <br /> 1.872 Tons (based on 77% sensible capacity) <br /> Notes <br /> ---------- <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> J <br /> Tuvvsdav, February 27.2001 <br />
The URL can be used to link to this page
Your browser does not support the video tag.