Laserfiche WebLink
40) 0,4". <br /> 1 r ,4 <br /> CITY of ORONO <br /> Municipal Offices <br /> � <br /> � ,, Street Address: Mailing Address: <br /> ��i <br /> 414i/311' 01. 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323.0066 <br /> Owner: Tohr\ fflt oy <br /> Address:2735 White Oak Cir. <br /> Permit 30 8 <br /> #'s:965 Dates:6 <br /> �� �� / / 8 Contractors:Ouverson <br /> (This is [)() an existing system [ ] new construction) <br /> SYSTEM COMPLIANCE (1-3) : 1 <br /> (! Code System: Meets or exceeds current City standards in all respects relating to <br /> design, construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, <br /> but in most respects appears to be designed, located, and constructed in accordance <br /> with previous codes and is functioning properly. <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the <br /> current input; and any system with less than three feet of vertical separation <br /> between the bottom of the drainfield and the saturated soil level. <br /> (The saturated soil level [ ] has or [ ] has not been identified at this time. If the <br /> saturated soil level has not been identified, this classification is subject to revision. ) <br /> TANK CONDITION (5-9) : 5 <br /> jt) Pumpout not needed at this time <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been <br /> pumped out within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If <br /> tanks have not been pumped out within three years, they should be pumped out now. <br /> (During the last septic tank Maintenance Pumpout the tanks [ ] were or ,[K] were not <br /> confirmed to be watertight by the licensed pumping contractor. If the tanks were not <br /> confirmed to be watertight, this classification is subject to revision.) <br /> DRAINFIELD CONDITION (11-14) : 11 <br /> 0 Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br /> Contact the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc. ) : low <br /> COMMENTS: <br /> Date of Inspection ep A System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue <br /> to function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />