My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1986 Septic System Info
Orono
>
Property Files
>
Street Address
>
W
>
White Oak Circle
>
2725 White Oak Cir - 04-117-23-42-0025
>
Septic
>
1986 Septic System Info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:14:21 PM
Creation date
2/3/2020 10:36:47 AM
Metadata
Fields
Template:
x Address Old
House Number
2725
Street Name
White Oak
Street Type
Circle
Address
2725 White Oak Cir
Document Type
Septic
PIN
0411723420025
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 01A (9' [E--' ii&L'-',1 ) <br /> iii AUG 3 1 1984 <br /> SITE EVALUATION REPORT U <br /> FOR GEORGE FUNK AND .� Y f F ORONO <br /> JUDY ROGOSHESKE IN <br /> ORONO, MINNESOTA ' <br /> 8-29-84 <br /> On August 25-29, 1984 three new lots were tested for both a <br /> primary and an alternate drainfield site in areas on the lots which <br /> should be fairly accessable from a proposed house location. All lots <br /> were fairly similar in that they had permeable soils, but a high <br /> seasonal water table as indicated by mottled soils . Thus, shallow <br /> trench systems would be needed on both the prii ry and alternate <br /> sites of each lot. Also, interceptor draintiles will be needed in <br /> order to divert runoff water from the sites. <br /> The percolation holes were dug 6 inches in diameter and usually <br /> 18-24 feet deep in order to test the soils just beneath the surface <br /> layer. Also, if an interceptor drain lowers the water table, the <br /> drainfield trenches could be placed nearer the tested level. <br /> The soil borings were dug 6 inches in diameter to the 4 foot <br /> depth and 4 inches in diameter to the 6 foot depth in order to <br /> tO determine the water table and the soils under the proposed <br /> drainfield trenches . <br /> Once the individual house sizes and locations are known on <br /> each of the lots, a more detailed system design will be needed. <br /> Meanwhile, if any other information is needed, please contact me . <br /> Sincerely, <br /> P7ERC OR, ,INC. <br /> vez # il'''` ` Mark S. Gronberg, P. <br /> 1 <br />