My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1997 - 009335 - mechanical
Orono
>
Property Files
>
Street Address
>
W
>
White Oak Circle
>
2720 White Oak Cir - 04-117-23-42-0020
>
Permits/Inspections
>
1997 - 009335 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:14:15 PM
Creation date
2/3/2020 9:57:29 AM
Metadata
Fields
Template:
x Address Old
House Number
2720
Street Name
White Oak
Street Type
Circle
Address
2720 White Oak Cir
Document Type
Permits/Inspections
PIN
0411723420020
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RHVAC-Residential&Light Commercial HVAC Loads Program NI Elite Softwore Development,Inc. <br /> Differ, Inc. KELLEY <br /> Hamel,MN 55340-9691 Page 2 <br /> Project Summary <br /> Company: DITTER INC. COOLING & <br /> HEATING <br /> Client: EMILY KELLEY Representative: DOUG BJORK <br /> Address: 2720 WHITE OAK CIR. Address: 820 TOWER DRIVE <br /> City: ORONO, MN. 55356 City: HAMEL, MN. 55340 <br /> Phone: 475-1280 Phone: 478-9558 <br /> Fax: Fax: 478-2426 <br /> Comment: Bid prepared by Doug Bjork <br /> Design Data <br /> Project Name: KELLEY <br /> Reference City: Minneapolis, Minnesota <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 Feet <br /> Outdoor Outdoor Indoor Indoor Grains <br /> Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference <br /> Winter: -20 N/A N/A 72 N/A <br /> Summer: 95 75 50% 75 36 <br /> Check Figures <br /> Total Building Supply CFM: 727 CFM per square foot: 0.631 <br /> Square feet of room area: 1,152 Square feet per ton: 627.071 <br /> Building Loads <br /> Total heating required with outside air: 25,866 Btuh 25.866 MBH <br /> Total sensible gain: 16,534 Btuh 88 % <br /> Total latent gain: 2,284 Btuh 12 % <br /> Total cooling required with outside air: 18,818 Btuh 1.568 Tons (based on sensible + latent) <br /> 1.837 Tons (based on 75% sensible capacity) <br /> Notes <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> Thursday,July 03, 1997 <br />