Laserfiche WebLink
vo 4. <br /> CITY OF ORONO O <br /> Municipal Offices O O <br /> Post Office Box 66 AI <br /> Crystal Bay, MN 55323-0066 ��y�f l ON—SITE SEWAGE TREATMENT <br /> "�' .`lIItpe• INSPECTION REPORT <br /> 0111" 4IP <br /> 11C 01.' <br /> Owner: Pay PC/...S7106 Address: v;/U 1ti14h Oa C <br /> Permit #'s: 47Dates: 9—"0- /6 Contractors: //Z/#c K7 Tke,r <br /> J <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. JJ <br /> (This is r/-3.,an existing system [ ] new construction) <br /> SYSTEM CONFORMITY (1-3): 7 <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> 4 g any pollutants into ground or surface waters. <br /> (3J "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The limiting soil characteristic j . has or [ ] has not been identified at this time. If the limiting soil <br /> characteristic has not been identified, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): 0 <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be puriped out this year to help prevent future problems. <br /> 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each <br /> tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). <br /> If tanks have not been pumped out within the last three years, they should be pumped out now. <br /> DRAINFIELD CONDITION (11-14): 11 <br /> ?I <br /> nfield inspection indicates: <br /> Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (slope,setbacks,etc.): /n).2,�pv.Z.Th <br /> POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): <br /> COMMENTS• Alce / . Ir r . 1a �.�E . ' 4 IIA Ar 4- • i"1 <br /> 7 ►��■If��lTr. �i-I���FNy�L�� itiliitelMiTJ��Ai�6i ' • .ICt II,, ifrL�iii/��ri �►�t / ,_ <br /> i. �� ; -L:t/►fs7! Ei�•APr!xariag :Ll/./// ri ///1 a M7.. i `L'• oi L t pc'J;S� <br /> 4 � L� eld <br /> Date of Inspection Se. is System Inspector w, uy ON- <br /> year <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly, but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> information. <br /> This report must be kept on the premises with the system location and pupping records. <br /> WHITE COPY!Inspectors File YELLOW COPY;Homeowner <br />