Laserfiche WebLink
Drainsafe DS 360 <br /> • <br /> Anti—Entrapment Type,Submerged Suction Outlet Cover <br /> Read these instructions in their entirety prior to starting installation <br /> ANSI/ASME A112.19.8(2005)Certified.Safe Flow Rate 123(GPM)Gallons Per Minute <br /> For use with suction outlet sumps up to 8 inch in size <br /> Note: read all instructions prior to installation.It is recommended this product be used in conjunction with an ANSI/ASME <br /> A112.19.17 Certified(SVRS)Safety Vacuum Release System,properly installed by a licensed pool professional. <br /> • Important Information: <br /> Do not exceed DS 360 Safe Flow Rate:123 gallons per minute. Post safe flow rate in an obvious location in pump room. <br /> Acceptable connecting pipe sizes:up to 2.5". <br /> Inspect this unit for proper attachment daily,inspect for fractured or damaged parts daily. • <br /> Never operate any pool/spa facility if drain cover is damaged,cracked,fractured,loose or missing. <br /> Use supplied 316 Grade S/S(12 per kit)security screws to install this anti-entrapment type drain cover. <br /> Ensure existing sump screw attachment holes are clean and free of debris prior to attachment. <br /> Carefully tighten screws to secure cover.Do not over tighten screws.Damage to the DS 360 could result,causing serious <br /> injury or death.If the DS 360 is damaged,do not start pump(s)until a new DS 360 unit is properly reinstalled. <br /> After slowly tightening supplied screws,be certain DS 360 cannot be moved side to side,vertically or horizontally to ensure <br /> secure attachment.Do not over tighten screws. <br /> !!!Read these instructions in their entirety prior to starting installation.Keep these instructions for future reference!!! <br /> Attempt this operation in a dry environment <br /> Do not install this product on seating or backrest of seating area. <br /> Do not place this product within three feet of another suction outlet on the same suction line or mounting plane. <br /> If one suction outlet should become blocked,the remaining suction outlets shall be capable of handling the flow of the system. <br /> Be certain pgol/spa pump(s)_are secured. <br /> Use battery operated drill(if need be),or a"yankee type"manual screw diver to pre-drill holes. <br /> Use supplied security tool and S/S 316 grade security screws. <br /> Do not increase flow through system by'increasing pump size or horsepower. <br /> Do not allow children to sit,play or interact with main drains or suction outlets. <br /> Optional tools:awl,1/16 inch drill bit,battery operated drill or a"yankee type"manual screw driver to predrill holes, <br /> brush and or dust pan to clean surface area prior to installation. <br /> Installation: <br /> remove existing main drain cover.Clean area and prep for DS 360 install. <br /> 1stall this product in aright side up position.ANSI/ASME A112.19.8(2005)labeling is on the top of the unit.Set DS 360 on sump <br /> id align existing screw holes with DS 360 screw ports(5.5 to 7.5 inch bolt centers)this configuration fits most common sump <br /> mew patterns.Outer edges must be flush with existing pool/spa linen Do not start pump if the edges of the DS 360 are not flush and <br /> ght to the existing liner be it;plaster,exposed aggregate,fiberglass,coated surface or vinyl. <br /> rsert the two supplied screws into the existing holes in the sump,(6 sets of screws included to match original OEM screws)hand <br /> ihten.(Do not overtighten!) <br /> den,using a 1/16 inch drill bit,drill approximately(2)1/4 inch deep holes,at a 90 degree off-set(screw holes pre drilled in DS 360 <br /> Iver)into the existing mud ring plastic,as close to the sumps frame as possible. <br /> 3e all four(4)screw ports to mount DS 360.Insert the other two matching OEM supplied screws,hand tighten only using the <br /> pplied uni-screw security tool. <br /> DO NOT OVER TIGHTEN SCREWS,AS THIS MAY DAMAGE <br /> THE DS 360 OR THE EXISTING SUMP!! • <br /> not install DS 360 if screws are not secured properly.Install the next screw size larger(supplied).It is important all four screw <br /> achment openings are utilized.In some cases it may require you to predrill four new screw ports for a secure fit. <br />