My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014 - 00968 - pool - in ground
Orono
>
Property Files
>
Street Address
>
W
>
Westlake Street (2)
>
364 Westlake St - 05-117-23-23-0043
>
Permits/Inspections
>
2014 - 00968 - pool - in ground
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:20:38 PM
Creation date
1/31/2020 10:55:53 AM
Metadata
Fields
Template:
x Address Old
House Number
364
Street Name
Westlake
Street Type
Street
Address
364 Westlake St
Document Type
Permits/Inspections
PIN
0511723230043
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TEL FL ° VSSS` .- S <br /> '> PENTAIR -IGH PERFORMANCE PUMPS <br /> "iiiPFeatured Highlights <br /> •Ability to program exact pump speeds for specific <br /> ECO® operations-filtering,heating,cleaning,spa jets,water <br /> S e 1 e a t features and more-reduces energy costs up to 90% <br /> j efficency'c a / • SVRS complies with Virginia Graeme Baker Safety Act <br /> �-� " PENTAIR <br /> • Builtin diagnostics protect the IntelliFlo pump from <br /> � the most common causes of premature failure- <br /> I. <br /> overheating,freezing,and voltage irregularities. <br /> LIFS (�1J rr/�r • Includes priming protection.No SVRS calibrations <br /> needed.Built-in SVRS cannot be turned off. <br /> __ ENERGY STAR • Safety lock-out feature(password protected) <br /> prevents pump speed settings from being changed by <br /> Appliance unauthorized personnel <br /> Efficiencytabs •Ability to set minimum and maximum speeds so pump <br /> 414 Database <br /> will only operate within the ranges set to help assure <br /> safe operation and long life <br /> 4 <br /> IntelliFloVS+SVRS pump Protected by U.S.Patent No.8,043,070;7,686,587; • Compatible with IntelliTouch®,EasyTouch®,and <br /> 7,815,420;7,857,600;7,854,597;D568,340;0606,562,D611,430 and Patent <br /> Pending and all corresponding foreign counterparts. SunTouch®Pool Control Systems <br /> IntelliFlo pumps combine variable speed technology, • NSF Certified,UL and ETL Listed as an <br /> onboard digital intelligence,and permanent magnet motors ASME A112.19.17.2002 Device <br /> (used in hybrid cars)to reduce pump-related energy costs • Operates seamlessly on 50 hz or 60 hinput power. <br /> by up to 90%.The IntelliFlo VS+SVRS pump models are Flow/speed are constant when operating on 50hz or 60 hz. <br /> the first swimming pool pumbs to feature a built-in Safety <br /> Vacuum Release System that detects drain blockage and <br /> automatically shuts the pump off. <br /> I <br /> ®rderong h,f rmation <br /> Full Load Primary Listings and Port Size Carton <br /> Product Model Voltage Amps kW HP SF SFHP FRED. Certifications' (NPTI Wt.(Lbs.) <br /> ULTRA ENERGY EFFICIENT VARIABLE SPEED WITH SAFETY VACUUM RELEASE SYSTEM <br /> 011017 IntelliFlo VS+SVRS 230 16 3.2 3 1.32 3.95 50hz/60hz UL',NSF''CSA',ASME',ETL, 2 in.x 2 in. 47 <br /> APSP' <br /> ACCESSORIES <br /> 520641 IntelliCom 4-Rated 15-240 VAC 15-100 VDC with 4 inputs 8 <br /> 521109 IntelliCom 2-Rated 9-30 V DC with 4 inputs 1 <br /> 350122 Communication Cable-50 ft.-Included with pump 2 <br /> 350250Z SVRS KIT-Allows use of discharge check valves with SVRS pump 1 <br /> UNIONS <br /> 11201-0154 2 in.x 2 in.Union(2 in.NPT male x 2 in.female NPT quick connect) *Note:two required per pump(sold individually] 2 <br /> ' 'UL'indicates that pump bears a UL mark signifying evaluation to U.S. Title 20 and is certified to use on Residential Swimming Pool Filtration <br /> Standards UL1081 for Permanently Connected Swimming Pool and Spa Systems. <br /> Pumps and to Canadian Standards CAN/CSA C22.2 No.108-01 Liquid 6 Product may have been evaluated to other state and local regulatory <br /> Pumps For Swimming Pools Only(Enclosure 3]. standards.Listing status may change.Always confirm status with <br /> 2 'NSF'indicates that pump bears a NSF mark signifying evaluation to NSF appropriate agency if in doubt. <br /> Standard 50 For Self-Priming Centrifugal Pumps For Swimming Pools Only. Note:Pump must be used with current collectors when installed on spas <br /> 3 'CSA'indicates that pump bears a CSA mark signifying evaluation to or hot tubs in Canada. <br /> Canadian Standards CAN/CSA C22.2 No.108-01 Liquid Pumps For Refer to catalog page 147 for the SVRS Test Mat Kit which saves time and <br /> Swimming Pools Only(Enclosure 3). helps to determine if a vacuum release system is functioning properly in <br /> n 'ASME'indicates that pump bears a specific mark signifying evaluation to a pool and spa. <br /> ASME/ANSI Standard A.112.19.17.2002 Manufactured Safety Vacuum Relief Refer to catalog page 36 fora selection of 1-and-2-Pole GFCI breakers <br /> System I$vRs). which offer 6 milliamp personnel protection while meeting 2008 to <br /> / <br /> ' 'APSP'Pump has been evaluated to ANSI/APSP/ICC-15 and California Current NEC Standards for Pool Pumps. <br />
The URL can be used to link to this page
Your browser does not support the video tag.