2014 - 00137 - new structure
Orono
>
Property Files
>
Street Address
>
W
>
Westlake Street
>
364 Westlake Street- 05-117-23-23-0043
>
Permits/Inspections
>
2014 - 00137 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:20:37 PM
Creation date
1/31/2020 10:26:42 AM
Metadata
Fields
Template:
x Address Old
House Number
364
Street Name
Westlake
Street Type
Street
Address
364 Westlake St
Document Type
Permits/Inspections
PIN
0511723230043
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OR <br /> * El.i, b . <br /> t . . <br /> .. <br /> New Construction Energy Code Compliance Certificate <br /> Per N1101.8 Building Certificate.A building certificate shall be posted in a permanently visible location inside Date Certificate Posted ,, „Si.,.. <br /> th <br /> ` '- <br /> the building. The certificate shall be completed by the builder and shall list information and values of <br /> components listed in Table N1101.8. 2/18/14 <br /> Mailing Address of the Dwelling or Dwelling Unit City `£ ,,$• <br /> 364 W Lake St. Orono <br /> LDK <br /> Name of Residential Contractor MN License Number <br /> -2,:,,,1( ,fjlr.f Ar'.1.1 e,,,r <br /> LDK Builders, Inc. BC001327 <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type:Check All That Apply X Passive(No Fon) <br /> o a) <br /> c <br /> a, v Active(With fan and monometer or <br /> 'T other system monitoring device) <br /> Co -o <br /> T <br /> f0 U C a, <br /> o a 3 u — o -a T. <br /> v a ° ,o -a u ai <br /> Q m m a, c ) -a ? <br /> ,o C O �i ;i p al i..� ,-8 <br /> Insulation Location • o Z o - o m w <br /> '=' 0 ,,,.,° no <br /> m• D c v a' E E c -d -o <br /> m c <br /> z � z L.0, l° 2 F2 E Other Please Describe Here <br /> Below Entire Slab R-10 X <br /> Foundation Wall R-5 X Exterior <br /> Perimeter of Slab on Grade X <br /> Rim Joist(Foundation)-BASF Comfort Foam® R-13 X Interior <br /> Rim Joist(1`t Floor+)-BASF Comfort Foam® R-13 X Interior <br /> Wall R-19 X <br /> Ceiling,flat R-44 X <br /> Ceiling,vaulted R-44 X <br /> Bay Windows or cantilevered areas-BASF Comfort Foam® R-30 X <br /> Bonus room over garage R-30 X <br /> Describe other insulated areas <br /> I I <br /> Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces <br /> Average U-Factor(excludes skylights and one door)U: 0.30 Not applicable,all ducts located in conditioned space <br /> Solar Heat Gain Coefficient(SHGC): 0.34 8 R-value(If Applicable) <br /> MECHANICAL SYSTEMS 1 Make-up Air Select a Type <br /> Appliances Heating System Domestic Water Heater Cooling System X Not required per mech.code <br /> Fuel Type Natural Gas Natural Gas R-410A Passive <br /> Manufacturer Bryant A.O.Smith Bryant Powered <br /> #1 987MA42060V17#2 #1 187BNA036 Interlocked with exhaust device. <br /> Model 987MA66120V24 GDHE-50 VERTEX+ #2 187BNA048 Describe: <br /> Input in #1=60K Capacity in 80 Output in 7 Other,describe: <br /> Rating or Size BTUS: #2=120K Gallons: Tons: <br /> Heat Loss: Heat Location of duct or system: <br /> Structure's Calculated 144'702 Gain: 56,430 <br /> AFUE or SEER: 16+ Mechanical Room <br /> HSPF% 97% <br /> Calculated 72,858 <br /> Efficiency cooling load: Cfm's <br /> ”insulated flex duct OR <br /> Mechanical Ventilation System "metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up furnace):2 Furnaces,2 A/C's,2 HRV's Not required per mech.code <br /> Select Type X Passive <br /> 2 Heat Recover Ventilator(HRV) Capacity in cfms: Low: 90(x2) High: 140(x2) Other,describe: <br /> Energy Recover Ventilator(ERV)Capacity in cfms: Low: High: Location of duct or system: <br /> Continuous exhausting fan(s)rated capacity in cfms: Mechanical Room <br /> Location of fan(s),describe: Cfm's <br /> Capacity continuous ventilation rate in cfms: 128 6 "insulated flex duct OR <br /> Total ventilation(intermittent+continuous)rate in cfms: 255 "metal duct <br /> Created by BAM version 052009 <br />