My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014 - 00137 - new structure
Orono
>
Property Files
>
Street Address
>
W
>
Westlake Street
>
364 Westlake Street- 05-117-23-23-0043
>
Permits/Inspections
>
2014 - 00137 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:20:37 PM
Creation date
1/31/2020 10:26:42 AM
Metadata
Fields
Template:
x Address Old
House Number
364
Street Name
Westlake
Street Type
Street
Address
364 Westlake St
Document Type
Permits/Inspections
PIN
0511723230043
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2014 Standardized Top of Foundation Wall Support Drawings <br /> SCOPE OF WORK: <br /> These drawings apply to the construction of top of full height cast-in-place concrete, insulated concrete form, and <br /> masonry basement foundation walls for typical residential cases. These drawings are not to scale and all conditions <br /> are to be verified by the contractor. Means and methods of construction for shoring, water-proofing, insulation, <br /> flashing, and all other non-structural requirements are to be by others in accordance with the Code and standard <br /> industry practice. These drawings are valid through December 31, 2014. <br /> The drawings are to only be used by the contractor noted below or his authorized sub-contractors/clients. These <br /> drawings are to be provided to the building inspection department as part of the permit package. <br /> INDEX: <br /> S1 -Scope, Index, and Certification <br /> S2 -General Notes <br /> S3 - Standard Bearing Wall Detail <br /> S4 - Standard Non-Bearing Wall Joist Blocking Detail <br /> S5 - Bottom Chord Bearing Truss Non-Bearing Wall Detail <br /> S6 -Top Chord Bearing Truss Non-Bearing Wall Detail <br /> MATERIALS: <br /> Concrete: Minimum 28 day compressive strength (F'c)of 3000 psi <br /> Masonry: Minimum 28 day prism strength (F'm)of 1500 psi <br /> Backfill Soil: Sand -30 psf/ft effective lateral pressure <br /> Sandy Clay-45 psf/ft effective lateral pressure <br /> Clay-60 psf/ft effective lateral pressure <br /> I hereby certify that this plan,specification,or report <br /> SITE ADDRESS: was prepared by me or under my direct supervision <br /> and that I am a duly licensed professional engineer <br /> under the laws of the state of Minnesota. <br /> Street: <br /> City: - ` <br /> State: MN Zip: Craig Oswell, PE(MN#42341) <br /> 1/1/2014 <br /> Oswell Engineering and Consulting, L.L.C. 1901 E Hennepin Ave,#201 x - . . <br /> Wa, <br /> Project Name: 2014 Standardized Top of Foundation Support Drawings Minneapolis, MN 55413 !}+' y <br /> Description: Scope of Work, Index, and Certification Phone: 612-720-4639 "'*•" _ <br /> Project# 13.100 Fax: 612-886-2966 ' <br /> Client Name: Abfalter Brothers Concrete LLC www.oswellec.com *° <br /> Client Address: 15546 Cleveland Street, Elk River, MN 55330 Page S1 of S6 „s,4,44.; ! ';y <br />
The URL can be used to link to this page
Your browser does not support the video tag.