Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
<br /> Metro Air Inc. *3Martens Residence
<br /> Prior Lake,MN 55372-3310 Page 5
<br /> y rY
<br /> System 1 Room Load Summa
<br /> ' T Htg Htg Run Run Cig Cig Clg Zone Clg Air
<br /> Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys
<br /> No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM
<br /> --Zone 1---
<br /> 1 Basement 1,894 14,910 233 0-0 0 1,640 153 77 1.00 77 77
<br /> 2 Great Room 355 14,880 232 0-0 0 6,917 355 324 1.00 324 324
<br /> 3 Dining Room 282 5,168 81 0-0 0 1,868 128 87 1.00 87 87
<br /> 4 Kitchen 194 2,644 41 0-0 0 957 52 45 1.00 45 45
<br /> 5 Master Bedroom 349 10,853 169 0-0 0 6,792 622 318 1.00 318 318
<br /> 6 Master Bath 135 3,151 49 0-0 0 943 37 44 1.00 44 44
<br /> 7 Walk In Closet 145 1,097 17 0-0 0 301 0 14 1.00 14 14
<br /> 8 Entry And Bath 132 2,157 34 0-0 0 489 64 23 1.00 23 23
<br /> 9 Laundry And 128 2,705 42 0-0 0 1,028 37 48 1.00 48 48
<br /> Closet
<br /> 10 Foyer 109 3,849 60 0-0 0 1,354 107 63 1.19 75 63
<br /> 11 Study 150 6,523 102 0-0 0 4,061 159 190 1.18 225 190
<br /> 12 Bedroom 2 263 5,735 90 0-0 0 2,778 247 130 1.00 130 130
<br /> 13 2nd Floor Bath 84 1,222 19 0-0 0 828 21 39 1.25 48 39
<br /> 14 Bonus Room 364 5,913 92 0-0 0 2,346 64 110 1.15 127 110
<br /> 15 Bedroom 3 198 4,539 71 0-0 0 2,293 238 107 1.18 127 107
<br /> Ventilation 19,374 4,506 2,495
<br /> System 1 total 4,782 104,72 1,332 39,101 4,779 1,620 1,713 1,620
<br /> 0
<br /> Cooling System Summary
<br /> Cooling
<br /> _Cooling Sensible/Latent Sensible Latent Total
<br /> Tons Split Btuh Btuh Btuh
<br /> Net Required: 3.66 89%/ 11% 39,101 4,779 43,880
<br /> Recommended: 4.34 75%/25% 39,101 13,034 52,134
<br /> C:\Elite\Rhvacw\Projects\lee-lyn martens.rhv Thursday, September 27, 2007, 2:09 PM