My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2007 - P11521 - mechanical
Orono
>
Property Files
>
Street Address
>
W
>
West Lafayette Road
>
2655 West Lafayette Rd - 21-117-23-24-0039/47
>
Permits/Inspections
>
2007 - P11521 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:05:03 PM
Creation date
1/29/2020 9:30:07 AM
Metadata
Fields
Template:
x Address Old
House Number
2655
Street Name
West Lafayette
Street Type
Road
Address
2655 West Lafayette Road
Document Type
Permits/Inspections
PIN
2111723240039
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Metro Air Inc. Martens Residence <br /> I Prior Lake,MN 55372-3310 Page 2 <br /> Project Report <br /> General Project Information <br /> Project Title: Martens Residence <br /> Designed By: Autumn Design <br /> Project Date: Thursday, September 27, 2007 <br /> Client Name: Lee-Lyn Construction <br /> Client Address: 729 Newton Ave SE <br /> Client City: Watertown, MN 55388 <br /> Client Phone: 952-955-3388 <br /> Company Name: Metro Air, Inc. <br /> Company Representative: Joe Storms <br /> Company Address: 16980 Welcome Ave. S.E. <br /> Company City: Prior Lake, MN 55372 <br /> Company Phone: 952-447-8124 <br /> Company Fax: 952-447-8126 <br /> Company Website: www.metroairmn.com <br /> Design Data <br /> Reference City: Prior Lake, Minnesota <br /> Daily Temperature Range: Medium <br /> Latitude: 43 Degrees <br /> Elevation: 822 ft. <br /> Altitude Factor: 0.971 <br /> Elevation Sensible Adj. Factor: 1.000 <br /> Elevation Total Adj. Factor: 1.000 <br /> Elevation Heating Adj. Factor: 1.000 <br /> Elevation Heating Adj. Factor: 1.000 <br /> Outdoor Outdoor Indoor Indoor Grains <br /> Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference <br /> Winter: -16 0 0 70 0 <br /> Summer: 95 72 50 75 18 <br /> Check Figures <br /> Total Building Supply CFM: 1,620 CFM Per Square ft.: 0.339 <br /> Square ft. of Room Area: 4,782 Square ft. Per Ton: 1,101 <br /> Volume (ft') of Cond. Space: 42,199 Air Turnover Rate (per hour): 2.3 <br /> Building Loads <br /> Total Heating Required With Outside Air: 104,720 Btuh 104.720 MBH <br /> Total Sensible Gain: 39,101 Btuh 89 % <br /> Total Latent Gain: 4,779 Btuh 11 % <br /> Total Cooling Required With Outside Air: 43,880 Btuh 3.66 Tons (Based On Sensible + Latent) <br /> 4.34 Tons (Based On 75% Sensible Capacity) <br /> rNotes <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> C:\Elite\Rhvacw\Projects\lee-lyn martens.rhv Thursday, September 27, 2007, 2:09 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.