My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1999 - 011165 - mechanical
Orono
>
Property Files
>
Street Address
>
W
>
West Farm Road
>
1889 West Farm Road - 27-118-23-43-0015
>
Permits/Inspections
>
1999 - 011165 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:22:35 PM
Creation date
1/27/2020 11:22:44 AM
Metadata
Fields
Template:
x Address Old
House Number
1889
Street Name
West Farm
Street Type
Road
Address
1889 West Farm Road
Document Type
Permits/Inspections
PIN
2711823430015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> RHVAC-Residential&Light Commercial HVAC Loads Program • Elite Software Development,Inc. <br /> ;Ditter,ince"" Whitten <br /> Flame',MN 55340-9691 Page 2 <br /> Project Summary <br /> Project: Whitten Company: Ditter Inc. Cooling & Heating <br /> Client: Ben Whitten Representative: Doug Bjork <br /> Address: 1889 West Farm Rd. Address: 820 Tower Drive <br /> City: Orono, MN. City: Hamel, MN. 55343 <br /> Phone: Phone: 478-9558 <br /> Fax: Fax: 478-2426 <br /> Comment: <br /> Design Data <br /> Project Name: Whitten <br /> Reference City: Minneapolis, Minnesota <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 Feet <br /> Elevation Sensible Adj. Factor: 1.000 <br /> Elevation Total Adj. Factor: 1.000 <br /> Outdoor Outdoor Indoor Indoor Grains <br /> Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference <br /> Winter: -20 N/A N/A 72 N/A <br /> Summer: 95 75 50% 75 36 <br /> Check Figures <br /> Total Building Supply CFM: 1059 CFM per square foot: 0.772 <br /> Square feet of room area: 1,372 Square feet per ton: 547.836 <br /> Building Loads <br /> Total heating required with outside air: 71,341 Btuh 71.341 MBH <br /> Total sensible gain: 23,141 Btuh 85 % <br /> Total latent gain: 4,229 Btuh 15 % <br /> Total cooling required with outside air: 27,369 Btuh 2.281 Tons (based on sensible + latent) <br /> 2.504 Tons (based on 77% sensible capacity) <br /> Notes <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> Thursday,December 31, 1998 <br />
The URL can be used to link to this page
Your browser does not support the video tag.