My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2001 - Septic System approval
Orono
>
Property Files
>
Street Address
>
W
>
West Branch Road
>
4760 West Branch Rd - 06-117-23-33-0002
>
Septic
>
2001 - Septic System approval
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:26:56 PM
Creation date
1/24/2020 1:41:04 PM
Metadata
Fields
Template:
x Address Old
House Number
4760
Street Name
West Branch
Street Type
Road
Address
4760 West Branch Rd
Document Type
Septic
PIN
0611723330002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
vvI< 95 - - 1 1 `! _ ,/ 7_5 <br /> /11 <br /> 8THIS ED MIS DESIGNED FO <br /> RDDMS, A R <br /> HALSTAD CONTRACTING OF Bi DROOMS INVALIDA Es E NUMBER <br /> 14180 NE 91ST STREET $DESIGN. <br /> ELK RIVER,MN 55330 <br /> 612-441-4085 <br /> April 15, 2000 <br /> Mike Rodtwald <br /> 4760 West Branch Road <br /> Orono, MN 55356 <br /> Re: Above Address <br /> The existing septic system on this lot is failing and needs replacement. The problem appears to be <br /> that the drainfield is plugged due to solids that have gotten into it. <br /> In the area designated for new mound treatment system, the soil is mainly loam topsoil. The perc <br /> rate averaged 10 MN and mottled soil was at 14"— 17". The system designed is for a 4 bedroom, <br /> Type I house. The system should include a 500 sq. ft. rock bed mound, 2 — 1,000 gallon septic <br /> tanks and a 1,000 gallon pump tank. <br /> The existing septic tanks should be pumped and filled at time of new installation. <br /> Approximate quantities needed: <br /> 100'-4" Schedule 40 pipe with cleanouts as required <br /> 2 - 1,000 gallon septic tanks <br /> 1 - 1,000 gallon pump tank <br /> 1 - Effluent pump(38 GMP at 15' total head) <br /> 1 - Sight and sound alarm <br /> 50'- 2" Schedule 40 pipe for supply line <br /> 150' — 1%2" or 2" Schedule 40 pipe for laterals <br /> 26 to 30 -Tons 1Y2" sewer rock <br /> 300-Tons washed sand <br /> 20-Tons sandy loam cap <br /> 100 - Yards loam to sandy loam topsoil (more may be needed to blend into existing <br /> grade at upslope) <br /> Geotextile fabric CITY OF ORONO. <br /> Pump septic tanks every 2 years. SEPTIC on=C 14XEW <br /> INSPECTOR ` ,�'C:__ C r. .� x; . <br /> DATE 4 PERMIT NO. <br /> Sincerely, APPROVED AS SUBMITTED <br /> ,/ APPROVED WITH CORRECTIONS AS NOTED <br /> OAANnil(/" NOT APPRQVED..CORRECT.4 RESUBMIT <br /> These comments iN for your hnformattae. AU week shalt be does <br /> In full compliance with all applicable septic and zoning code. <br /> Duane Halstad Requirements including items not specifically noted is ibis mina <br /> MPCA 764/1031 I iaP TW$PLAN WON SITS/4ALL TIMES <br /> DMH:jh <br />
The URL can be used to link to this page
Your browser does not support the video tag.