My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009 - 00720 - new septic
Orono
>
Property Files
>
Street Address
>
W
>
West Branch Road
>
4701 West Branch Rd - 07-117-23-22-0016
>
Septic
>
2009 - 00720 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:32:25 PM
Creation date
1/24/2020 12:39:18 PM
Metadata
Fields
Template:
x Address Old
House Number
4701
Street Name
West Branch
Street Type
Road
Address
4701 West Branch Rd
Document Type
Septic
PIN
0711723220016
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pressure Distribution Design Worksheet : <br /> 1. Select Number of Perforated Laterals: 3 <br /> Geotextile <br /> w sacro Minimum►..�yf ;6►...firm§ <br /> 2. Select Perforation Spacing: 3.0 ft '/.'perforations spaced 3'apart.7,..r.., 2.of rock:•-•.2-.-.-, ,.:1,9:;....2,0e0.1- <br /> 3. Select Perforation Diameter 7/32 inc1.,,...!...!..L--; ..ter v .-. /, y_., - __ 12" <br /> ��i�a.r i�t+iraa� i i .'�.iia-� �jJ,g <br /> D' . . r.- . i 11:�, 9 of narks..jam`.it ►.j�D�.:r6( <br /> 4 Length of Laterals=Media Bed Length-2 Feet ! ., { { > '♦ 1.F'41:0--4-4. <br /> ri`:0--4?.ss-.. rl . i= a <br /> r� n nPr, <br /> 63 - 2ft = 61 ft Perforation sizing:'/.'to 4." <br /> Perforation spacing:2'to 3' <br /> 5. Determine the Number of Perforation Spaces. Divide the Length of Laterals(Line 4)by the Perforation Spacing(line 2)and round down to the nearest whole number. <br /> Number of Perforation Spaces= 61 ft 3 ft = 20 Spaces <br /> 6. Number of Perforations per Lateral is equal to 1.0 plus the Number of Perforation Spaces(line 5). <br /> Perforations Per Lateral= 20 Spaces . 1 21 <br /> Check Table I to ensure that the number of perforations per lateral guarantees less than a 10%discharge variation. <br /> Table I Maximum Number of Perforations Per Lateral to Guarantee c10%Discharge Variation <br /> '/.Inch Holes s/„Inch Holes '4 Inch Holes <br /> Perforation Pipe Diameter(Inches) Perforation Pipe Diameter(Inches) Perforation Pipe Diameter(Inches) <br /> Spacing(Feet) 1 114 114 2 3 Spacing(Feet) 1 114 115 2 3 Spacing(Feet) 1 114 114 2 3 <br /> 2 10 13 18 30 60 2 12 18 26 46 87 2 21 33 44 74 149 <br /> 214 8 12 16 28 54 214 12 17 24 40 80 214 20 30 41 69 135 <br /> 3 8 12 16 25 52 3 12 16 22 37 75 3 20 29 38 64 128 <br /> 7. Total Number of Perforations equals the Number of Pet/mations per Lateral(Line 6)multiplied by the Number of Perforated Laterals(Line 1). <br /> 21 Perforations Per Lateral X 3 Number of Perforated Laterals = 63 Total Number of Perforations <br /> Calculate the Square Feet per Perforation Table IL Table Ill <br /> Recommended value is 6-10 ft2 per perforation. Does not apply to At-Grades Volume of Liquid in Pipe Perforation Discharge(GPM) <br /> 8. Bed Area = Bed Width(ft)X Bed Length(ft) <br /> Head Perforation Diameter <br /> 10 ft X 63 ft 630 Pipe Diameter Liquid Per Foot (ft) v/a /ha r/rz V4fe (inches) (Gallons) <br /> 9. Square Foot per Perforation=Bed Area(Line 8)divided by the Total Number of Perforations(Line 7). <br /> i 0.045 1'� 0.18 0.41 0.56 0.74 <br /> 630 ftt 63 perforations - 10.00 <br /> ft2/perforations 1.25 ovals 2.0° 0.26 0.59 0.80 1.04 <br /> 1.5 0.110 5.0' 0.41 0.93 1.26 1.65 <br /> 10. Select Minimum Average Head: 1.0 ft <br /> 2 0.170 <br /> a:Use 1.0 for dwellings using 1/4 inch or <br /> 3 0.380 3/16 inch holes. <br /> 11. Select Perforation Discharge(GPM)based on Table III: 0.56 GPM per Perforation <br /> 4 0.661 b:Use 2.0 for dwellings using 1/8 inch <br /> holes,or,for other establishments using <br /> 12. Determine required Flow Rate by multiplying the Total Number of Perforations(Line 7)by the 1/4 inch or 3/16 inch holes. <br /> Perforation Discharge(line 11). <br /> c:Use 5.0 for other establishments using <br /> 63 Perforations x 0.56 GPM per Perforation= 36 GPM 1/8 inch perforations. <br /> manifold pipe 1 <br /> 13. Select Type of Manifold Connection(End or Center): Center <br /> I <br /> 14. Select Minimum Diameter of laterals based on Table I: 1.50 in ` pipe from pump <br /> Determine Volume of Distribution Piping L.► <br /> 15. Pipe Diameter of Distribution Pipe 1.50 dean outs - t <br /> in <br /> 16. Volume of Liquid Per Foot of Distribution Piping: 0.110 Gallons L.- aftegate of pipe fropump <br /> 17. Length of Laterals=[Number of Perforations per Lateral-i)X Perforation Spacing __Ckvaam --- ------ <br /> 20 - 1 )( 3.0 ft = 57 ft J <br /> manifold pipes 1 <br /> 18. Volume of Distribution Piping= .,e. ' J <br /> -[Number of Perforated Laterals(Line 1)X Length of Laterals(Line 17)X ' -...'s'ac- ----- <br /> (Volume of Liquid Per Foot of Distribution Piping(line 16)] ��� \= ....----_ <br /> Aiternate location <br /> 3 X r 57 I X 0.110 = 18.81 Gallons N......- of pipe from pump <br /> '�" ripe from pump <br /> I hereby certify that I have completed this work in accordance with all applicable ordinances,rules and laws. <br /> Joseph J Olson810 112912008 <br /> (Oesigner) (:---a) (License ti) (Date) <br />