Jesse Struve <br /> From: Jesse Struve ORONOSent: Friday, February 15, 2013 3:57 PM COPY <br /> To: Melanie Curtis <br /> Cc: Christine Mattson <br /> Subject: 20130215 4700 West Brand Rd <br /> Melanie, <br /> I have reviewed the survey for proposed retaining wall and deck for 4700 West Branch Rd and have the following <br /> comments: <br /> • The retaining walls appear to all be sized at exactly 4' in height. If the walls are installed over 4' or if tiered walls <br /> are not separated by more than 2x the height of the taller wall (as measured from the face of the upper wall to <br /> the back of the lower wall),then the walls will need to have a registered professional engineer design plans and <br /> specification for the retaining walls. <br /> • Is the proposed deck elevated or will there be grading around the deck? <br /> Jesse Struve, PE <br /> Director of Public Works/City Engineer <br /> City of Orono <br /> (952) 249-4661 - Direct <br /> (952) 249-4616- Fax <br /> www.ci.orono.mn.us <br /> 1 <br />