Laserfiche WebLink
THERMAL lik COMPANY % .. A <br /> Customer Name 2�/&C..(• (9iA/C /1'(L, )! Address 4,4-:- ()-:- () • 4.).-....7,16-4, / b( <br /> J C/791 •&'7.re/ TTAMS. II - CONSTRUCTION FACTORS - IHEATINGCOn.INO NOTES & CALCULATIONS <br /> City C---)r04 U Slate `y//7• Zip Telephone <br /> HEATING COOLING, FACIoR <br /> •�`'' IAlrl'III TYPE 01 CIYISI'KIIC1'In', (F TI'II' DIFF) 46 <br /> (,,r •� <br /> Winter: Inside Design Temp F - Outside Design Temp/G}F ?/'� 7D G'j/ X Z -`J\( <br /> 15 20 25 <br /> Summer: Outside Design Temp _ F - Inside Design Temp _ F - =D WAILS (OSE SI). F'r.) <br /> HEATING DATA SECTION COOLING WALLS - WOOD FRAME W/ SHEATHING d SIDING. /0\7(3) //�/ /,� <br /> BTUH Heating Subject Sq. Ft. Cooling BTUH 2.5 A) NO INSULATION 5.5 7.0 9.0 <br /> Loss Factor �/�// Factor Gain 1.1 B) 1 1/2" INSULATION R-5 3.5 4.5 5.5 <br /> GROSS WALL /�42 1.0 C) 2" INSULATION R-7 3.0 3.5 4.5 <br /> /crag DOORS & WINDOWS (Table A8B) // I 0.6 D) 3 1/2" INSULATION R-13 2.0 3.0 3.5 <br /> 0.5 E) EXPANDED POLYSTYRENE SHEATHING R-13 2.0 2.7 3.3 � I <br /> /` i . NET WALL �/T ti <br /> �/I �j 0.4 F) 6" INSULATION R-30 1.8 2.3 3.0 �I-;�� t 1'' <br /> ,`" ir- + ! ABOVE GRADE - BSMT WALL / 0.2 C) 12" INSULATION R-44 .4 .5 .6 <br /> 4;:i<1 , / .. BELOW GRADE - BSMT WALL AZT. <br /> �� 4.5 SOLID MASONRY WALL, BLOCK/BRICK, PLASTERED/PLAIN 9.5 12.0 14.5 1-1-7f.,�'Y,' <br /> //4) <br /> / / CEILING ` 2.9 SOLID MASONRY WALL, BLOCS/BRICK, FURRED (NO INSCL) 6.5 8.0 10.0 F;, , ` G)! <br /> r FLOOR - BSMT OR CRAWL SPACE / 1.3 SOLID MASONRY WALL, FURRED 8 1 1/2" INSUL R-5 3.5 4.5 5.5 <br /> - /) 0.3 SOLID MASONRY WALL, FURRED & 6" INSUL R-30 .5i 4-. <br /> x'/17 �� FLOOR - SLAB � \/ .6 .8 I''' (.�, . .� <br /> J` ( SUB-TOTAL BTUH LOSS <br /> BASEMENT WALLS <br /> Jvj <br /> XADJUSTMENT FACTOR (Table C) C rif I ��_ <br /> ttyy 5.1 A) ABOVE GRADE - NO INSULATION 10.0 13.0 16.0 // <br /> .d70 TOTAL BTUH LOSS 1.8 B) ABOVE GRADE W/ 3/4" POLYSTYRENE R-5 2.8 4.1 5.3 ! `f/ ( <br /> PEOPLE X 300 BTUH GAIN (Note 1) 1.4 C) ABOVE GRADE W/ R-5 BATTS 2.5 3.6 4.7 <br /> APPLIANCE BTUH 1200 0.7 D) ABOVE GRADE W/ R-13 FIBER INSULATION 1.8 2.6 I 3.3 <br /> - 0.6 E) BELOW GRADE - NO INSULATION 0 0 0 <br /> SUB-TOTAL BTUH GAIN (Sensible) _ <br /> 0.4 F) BELOW GRADE W/ R-5 POLYSTYRENE 0 0 0 <br /> S 1.15 DUCT LOSS / GAIN (Note 2) (Note 3) 11.15 <br /> 0.2 G) BELOW GRADE W/ R-13 INSULATION 0 0 0 <br /> SUB-TOTAL BTUH GAIN (Sensible) CEILINGS (USE SQ. FT.) <br /> LATENT HEAT REMOVAL (sub-total X 1.3) E 1.30 <br /> �,-, 6.0 A) NO INSULATION 9.0 10.0 11.5 <br /> 4.7 S/ TOTAL BTUH LOSS / GAIN <br /> 1.4 B) 2" - 2 1/2" INSULATION R-7 4.0 4.0 4.5 <br /> Note 1 - Assume 2 persons per bedroom <br /> Note 2 - Calculate only if duct is located in an unconditioned space 0.8 C) 3" - 3 1/2" INSULATION R-I1 2.5 3.0 3.0 <br /> Note 3 - For crawl space or basement use 1.05 multiplier in COOLING 0.5 D) 5 1/4" - 6 1/2" INSULATION R-19 <br /> 1.5 2.0 2.0 <br /> 0.4 E) 6" - 7" INSULATION R-22 1.5 1.51 1.5 <br /> NEW CONSTRUCTION WORKSHEET 0.32 F) 8" - 9 1/2" IMSL'LATION R-30 1.1 1 1.3 1 1.3 1 <br /> 0.25 G) 10" - 12" INSULATION R-39 1.01 1.01 1.0 <br /> TABLE A - HEATING - DOORS A WINDOWS TABLE B - COOLING - DOORS 8 WINDOWS 0.22 H) 12" - 13" INSULATION R-44 I .8 .91 1.0 <br /> 0.35 I) CATHEDRAL TYPE R-26 (ROOF/CLNG COMBINATION) 1.4 1.51 1.7 <br /> WINDOW 8 DOOR TYPE HEATING I AREA - BTUH LOSS SINGLE CLASS DOUBLE GLASS TRIPLE CLASS <br /> FACTORS TEMP. DIFF TEMP. DIFF TEMP. DIFF I AREA = BTUH GAIN ' FLOORS (USE SQ. FT OR LINEAR FT) <br /> DOUBLE HUNG .75 CFM/FT DIRECTION 15 20 25 15 20 25 15 20 25 FLOORS OVER UNCONDITIONED SPACE (USE SQ. FT.) <br /> -- SINGLE GLASS 15.0 N 20 25 30 15 20 20 12 14 16 <br /> 1.6 A) OVER UNCONDITIONED ROOM 2.5 3.5 5.0 <br /> -- DOUBLE GLASS 9.5 <br /> (.26-V NE 8 NW 35 40 45 30 35 35 24 26 28 <br /> 2.8 B) OVER VENTED SPACE OR BSMT/GARAGE, NO INSUL 3.5 5.0 7.0 <br /> -- SINGLE W/STORM 9.0 B 8 W 55 55 60 45 50 50 36' 38 40 0.9 C) OVER VENTED SPACE OR BSMT 2" INSUL R-7 1.0 1.5 2.0 <br /> -- TRIPLE GLASS 7.0 SE 8 SW 45 50 55 40 40 45 30 32 34 <br /> 0.7 D) OVER VENTED SPACE OR BSMT 3" INSUL R-11 .5 1.0 1.5 <br /> -- DOUBLE V/STORM 6.0 S 30 30 35 25 25 30 18 20 22 <br /> 0.4 E) OVER VENTED SPACE OR BSMT 6" I1SLL R-19 .5 1.0 1.0 <br /> FIXED -- SINGLE 14.0 DOORS 13 13 13 1.4 F) OVER BSMT OR ENCLOSED CRAWL SPACE (NOT VENTED) 0 0 0 <br /> -- DOUBLE 8.5 /` <br /> ll TOTALS 0.3 BASEMENT FLOORS (USE SQ. FT.) 0 0 0 <br /> -- TRIPLE 5.5CONCRETE SLAB FLOOR UNHEATED (USE LIN. FT.) <br /> JALOUSIE W/STORM 22.0 7.5 A) NO EDGE INSULATION 0 0 0 <br /> SLIDING GLASS DOOR 1.0 CFM/FT TABLE C - ADJUSTMENT FACTORS - SEATING 6.0 B) 1" EDGE INSULATION R-5 0 0 0 <br /> -- SINGLE GLASS 16.5 5.0 C) 2" EDGE INSULATION R-9 0 0 0 <br /> F TEMPERATURE DIFF 30 40 50 60 70 80 90 <br /> -- DOUBLE GLASS 12.5 CONCRETE SLAB FLOOR DUCT IN SLAB (USE LIN. FT.) <br /> ADJUSTMENT FACTOR 3 4 5 6 7 8 9 <br /> WOOD DOOR ONLY 45.0 19.0 A) NO EDGE INSULATION 0 0 0 <br /> 11.5 0) 1" EDGF. INSULATION 0 0 0 <br /> WOOD DOOR/STORM OR TABLE I - DESIGN TEMPERATURES <br /> WS (WEATHERSTRIP) 24.0 - 9.5 C) 2" EDGE INSULATION 0 0 0 <br /> ((��(�� <br /> WOOD DOOR/STORM 8 VS 13.0 11 /9 CITY WIN SMR CITY WIN SMR - <br /> .J HEATING FACTORS FIGURED FOR A 10 F TEMPERATURE DIFFERENCE <br /> MPLS/ST. PAUL -16 89 DENVER -05 91 <br /> DOOR INSULATED CORE DULUTH -21 82 ENGLEWOOD -05 91 <br /> 11/5 W/STORM A WS 11.5 1I001 FALLS -15 91 COLORADO SP. -03 88 <br /> SIOUI CITY -II 92 GRAND JUNCTION ♦02 94 <br /> DOOR INSULATED CORE EAU CLAIRE -IS 89 CASPER -11 92 <br /> ROCHESTER -18 87 FORT COLLINS '-10 91 <br /> 1/5 W/STORM OR WS 22.5 MILWAUKEE -08 84 OAK PARE 03 88 <br /> GREEN BAT -13 85 LANSING -03 87 <br /> l`I MADISON -11 88 CHICAGO <br /> A 87 <br /> TOTALS U CEDAR RAPIDS -10 88 CHICAGO -08 91 <br /> DAVENPORT -11 88 ARLINGTON REIGRTS -07 91 <br />