My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2004 - Septic System Approval
Orono
>
Property Files
>
Street Address
>
W
>
West Branch Road
>
4640 West Branch Rd - 06-007-23-33-0008
>
Septic
>
2004 - Septic System Approval
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:03 PM
Creation date
1/24/2020 9:54:58 AM
Metadata
Fields
Template:
x Address Old
House Number
4640
Street Name
West Branch
Street Type
Road
Address
4640 West Branch Rd
Document Type
Septic
PIN
0611723330008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rusty Olson's--Soil and Percolation Testing <br /> Joseph J. Olson--MICA License#810 <br /> 11481 Riverview Rd. NE, Hanover, MN 55341 <br /> (763)498-8779 Fax(763)498-8290 <br /> April 29, gs„ — 11%9 —c 5 AA)" Vu�S�7`' "/S <br /> Mike Schultelte <br /> 4640 West Branch Road d 44Z-4-- <br /> Orono,Henn.Co. <br /> This on-site Sewage Treatment System is designed for a Type 1. four bedroom home in accordance with the <br /> Minnesota Pollution Control Agency Chapter 7080 and local ordinances. <br /> The soils on this site are SCS soils mapped-KkB-Kilkenny Loam.The seasonally saturated soils were located at <br /> 14"-20"(mottled soil). Due to seasonally saturated soils,a pressurized Mound System will need to be installed to <br /> treat septic effluent. The bottom of the treatment area must he located at least 3' above the saturated soils. <br /> The soils at a depth of 12"have a percolation rate averaging 10 MPI. <br /> All neighboring wells are located greater than 100' away from proposed treatment area • <br /> The existing tank must be abandoned. <br /> The existing system does not conform to chapter 7080. <br /> A pumping chamber will need to be installed to lift the effluent to the treatment area. The power supply and <br /> switches must be located outside the manhole and pumping chamber in a weatherproof enclosure. A warning device <br /> must be installed with light and sound devices;this is in case of a pump failure. <br /> The manifold and supply line must have back drainage to the pumping chamber. The distribution pipes shall have <br /> their ends capped. Be sure the rock and sand fill materials are clean. The sod layer below the entire mounded area <br /> must be turned over,just break up the sod and be sure not to over work. <br /> Keep all heavy equipment off of the proposed treatment area before during and after construction. This <br /> Design is not valid and the System will need to be relocated if failure to protect the area proposed for On-Site <br /> Sewage Treatment occurs. <br /> With proper installation and maintenance,this system should have no problem in treating septic effluent effectively. <br /> Nothing other than gray water.(laundry.showers.etc.) Human water and toilet tissue should he disposed of into the <br /> septic tanks. Garbage disposals are not recommended. Additives must not be used;they may cause harmful damage <br /> to your septic system. It is recommended that you pump the tank every year for I tank every two years for two tanks. <br /> Sincerely, <br /> i /2re � <br /> Joseph J. Olson CI a a OF ORONO <br /> DTIC P RMI P N REVIEW <br /> INSPECTOR 9Nori)- <br /> DATE a- 1 `j PERMIT N0..,,.......M......,,. <br /> APPROVED AS SUBMITTED <br /> APPROVED WITH CORRECTIONS AS NOTED <br /> NOT APPROVED-CORRECT A RESUBMIT <br /> nem ememe is we far yaw infortnatioe. MI work shall be does <br /> Is full coispliasee tritb all applicable septic and toning code. <br /> Ptequhvments ineludtng Items not specifically noted in this review. <br /> MP Tills PLAN SAT ON SITE AT AL3.TIMES <br />
The URL can be used to link to this page
Your browser does not support the video tag.