Septic System
Orono
>
Property Files
>
Street Address
>
W
>
Webber Hills Road
>
2120 Webber Hills Rd - 03-117-23-34-0010
>
Septic
>
Septic System
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:37:18 PM
Creation date
1/23/2020 10:18:07 AM
Metadata
Fields
Template:
x Address Old
House Number
2120
Street Name
Webber Hills
Street Type
Road
Address
2120 Webber Hills Rd
Document Type
Septic
PIN
0311723340010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' PRESSURE DISTRIBUTION SYSTEM <br /> 1. Select number of perforated laterals 3 <br /> 2. Select perforation spacing = ...3 ft. <br /> 3. Since perforations should not be placed closer than 1 ft. to <br /> the edge of the rock layer (see p: E-14), subtract 2 ft. from the <br /> rock layer length. <br /> 0 <br /> Rock layer gth - 2ft. = 48 ft. <br /> 4. Determine the number of spaces between perforations. <br /> Divide the length above by perforation spacing and round E-17a <br /> down to nearest whole number. TABLE OF PERFORATION DISCHARGES IN CI <br /> Head Perforation diameter(inches) <br /> Length perf. spacing =15 ft. ÷ 3 ft. = /,spaces 7/32 1/4 <br /> (3) (2) 1.0a 036 0.74 <br /> 1.5 0.69 0.90 <br /> 5. Number of perforations is equal to one plus the number of 2.0b 0.80 1.04 <br /> 2.5 0.89 1.17 <br /> perforation spaces . 3.0 0.98 1.28 <br /> 4.0 1.13 1.47 <br /> 5.0 1.26 1.65 <br /> /4 spaces + 1 = / 7perforations/lateral aUse 1.0 foot of head for residential systems. <br /> bUse 2.0 feet of head for other establishments <br /> 6. Multiply perforations per lateral by number of laterals to <br /> get total number of perforations.yE-17b <br /> M_=.uwab maeu ef�urr mce psea.om per Waal to <br /> X -L- = s� erforations. `tO t C5"`." aa <br /> laterals perfs/lateral h p""l y�°"°' 1.25 inch 1.5 inch 2.0 inch <br /> 2.5 14 18 28 <br /> 7. Determine required flow rate by multiplying 3.0 13 17 26 <br /> number of perforations by flow per perforation 4.0 11 15 23 <br /> (see page E -17) , 5.0 10 14 22 <br /> .S/ x .74 _. � m. <br /> pcfs gpm/pert E-15 <br /> 8. If laterals are connected to header pipe as shown on page E- <br /> 15, select minimum required lateral diameter from table on ?�,.,.• <br /> page E-17; enter table with perforation spacing and number ��. �, ,.•,'' a- <br /> of perforations per lateral. Select minimum diameter for \------ <br /> perforated lateral = L inches. <br /> E-12 <br /> 9. If perforated lateral system is attached to manifold pipe near c{ ....- <br /> the center,center, as on page E-12, perforated lateral length and <br /> number of perforations per lateral will be approximately one ���'"'- .. <br /> ..l:rL= <br /> half of that in step 8. Using these values, select minimum - . ,�,.. <br /> diameter for perforated lateral from page E-17 as Z.. �,.- "'r <br /> inches. <br />