My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1993 - Septic System approval
Orono
>
Property Files
>
Street Address
>
W
>
Wear Lane North
>
160 Wear Lane North - 33-118-23-34-0014
>
Septic
>
1993 - Septic System approval
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:50:56 PM
Creation date
1/21/2020 2:37:24 PM
Metadata
Fields
Template:
x Address Old
House Number
160
Street Name
Wear
Street Type
Lane
Street Direction
North
Address
160 Wear Lane North
Document Type
Septic
PIN
3311823340014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
View images
View plain text
Koch's Soil Testing <br /> P.O. Box 81 <br /> Loretto, MN 55357 <br /> Vintage Builders Inc . Tel: (612) 479-2637 10/8/93 <br /> 8401 73rd Ave. N <br /> Suite 90 <br /> Irpls . Minn. <br /> Job Site; Lot 1 , Blk 2 , Rolling Meadows Addition, Orono , Minn. <br /> Percolation tests amd soil borings were done on the above lot <br /> in 5/13/88 and on 11/29/90. It was determine that a mound system <br /> would be needed on this lot due to the mottled soil levels <br /> at 18-26 inches and the percolation rates were 72 min/in and 62. 7 min/in. <br /> The City of Ororno requires that the minnimum depth to mottled soil <br /> be at 54 inches and the maximum allowable perc. rate be 60 min/in. <br /> before a standard,trench system can be installed . <br /> v <br /> The size of mound system needed for a 5 bedroom home ( based on 750 <br /> gal/day daily water useage and •a perc . rate 72 min/in. the sizing factors ) <br /> would be 92 ft. hong'-on the upslope, 128 ft. long on the downslope <br /> and 62 ft. wide. The size of the rock bed needed would be 19 ft. wide <br /> by 68 ft. long ( 680 sq. ft. ) or 37 tons of rock is needed . <br /> See the enclosed design data for the specifications for the proposed <br /> system. <br /> This mound must be presssurized therefore a pump tank ( 1250 gallon) <br /> and a pump( 50g.p.m.- 214 gal/cycle- 4 cyc ;es/day) must be installed . <br /> An alarm system ( both a sound and a light alarm ) must be installed <br /> in the house to indicate pump failure. <br /> Two 1250 gallon sealed septic tanks must be installed , these tanks <br /> should be pumped out evry 2-3 years . <br /> every <br /> Only clean wash sand should be used in this mound , therefore this <br /> sand should be ♦:checked out by the local inspector to make sure it <br /> meets the specifications . <br /> All construction traffic must be kept off both sites to avoid <br /> compaction of the soils which will result in ruining the sites. <br /> Therefore both sites should be roped off by the builder. <br /> Site Evaluator <br /> Robert A Koch <br /> elt31-47—Caleadt) <br /> Robert KochMPCA Certified <br />