Laserfiche WebLink
t' R <br /> o CITY of ORONO <br /> iStreet Address: Mailing Address: <br /> O? 0 2750 Kelley Parkway PO Box 66 <br /> \ Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> 1 11` 401,,.. t <br /> H119.4, • Residential Energy <br /> effective June 1, 2009 <br /> Information Handout <br /> Attic thickness markers. The thickness of blown in or Building certificate. A building certificate shall be posted <br /> sprayed roof/ceiling insulation shall be written in inches on in a permanently visible location inside the building. The <br /> markers that are installed at least one for every 100 sq ft certificate shall be completed by the builder and shall list <br /> throughout the attic space. The markers shall be affixed information and values of components listed in the table <br /> to the trusses or joists and marked with the minimum initial below. <br /> installed thickness with numbers a minimum of 1 inch <br /> high. Each marker shall face the attic access opening. Component Certificate requirements <br /> Spray polyurethane foam thickness and installed R-value Date certificate is installed Posted date <br /> shall be listed on the certificate provided by the insulation Dwelling or dwelling unit Mailing address and city <br /> installer. location <br /> Residential contractor Name and license number <br /> Attic insulation card. A signed and dated insulation of residential contractor <br /> receipt attic card must be attached to the framing near the Insulation installed in or on Type and installed R-value <br /> access opening, in a clearly visible place and posted with ceiling/roof, walls, slab-on- <br /> the building certificate. The attic card must identify the grade and floor <br /> type of insulation installed, the manufacturer, the installer, Rim joist and foundation Installed R-value, type and <br /> the R-value per inch, the designed settled thickness, the wall insulation whether the insulation is <br /> square footage of attic coverage area and the number of exterior, integral or interior <br /> bags installed. Fenestration Average U-factor and <br /> SHGC <br /> Ducts outside conditioned Installed R-value <br /> spaces <br /> Mechanical ventilation Type, location and design <br /> system continuous and total <br /> ventilation rates <br /> Make-up air and Type, location and size <br /> iiiilAti66, <br /> combustion air systems (if <br /> installed) <br /> Heating system Type, input rating, AFUE or <br /> HSPF, manufacturer, model <br /> It II and the structure's <br /> calculated heat loss <br /> Domestic water heater Type, size, manufacturer <br /> and model <br /> Cooling system (if installed) Type output rating, SEER, <br /> manufacturer, model, <br /> t calculated cooling load and <br /> the structure's calculated <br /> heat gain <br /> Radon control system Passive or active <br /> Telephone (952) 249-4600 • Fax (952) 249-4616 • www.ci.orono.mn.us <br />