Laserfiche WebLink
/ o <br /> 7 0 <br /> CITY of ORONO <br /> .,, <br /> \\"� V iI H li Municipal Offices <br /> 4 Street Address: clsa—a4 <br /> `4 -Lk 60 O Mailing Address: <br /> � :% 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: r _ &) <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): <br /> I "CODE SYSTEM"An ISTS which meets all the location,design and construction standards of the current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): 5 <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped c7 • 7. — U' 3 ). <br /> Make sure septic tanks are pumped through manhole and not through white inspection pipes. This allows for the proper <br /> cleaning. Keep water softner and iron filter discharge out of septic system to prolong life of drainfield. Ask pumper to test <br /> alarm float to verify alarm is still working in your house. The alarm warns owner that septag_e is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDITION(8-10): d <br /> 8 Drainfield is dry,no surfacing evident. <br /> 9 Some evidence of surfacing, not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> COMMENTS: <br /> Date of Inspection Septic System Inspector <br /> Nr,,p rn the went thst this insnection report is used to satisfy the reauirements for a mortsase or other transfer of property_ be advised that this report does <br />