My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015 - 01027 - new/replacement septic
Orono
>
Property Files
>
Street Address
>
W
>
Wear Lane
>
20 Wear Lane - 04-117-23-21-0005
>
Septic
>
2015 - 01027 - new/replacement septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:08:27 PM
Creation date
1/17/2020 1:49:26 PM
Metadata
Fields
Template:
x Address Old
House Number
20
Street Name
Wear
Street Type
Lane
Address
20 Wear La
Document Type
Septic
PIN
0411723210005
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSPECTOR CHECKLIST - mound <br /> iu wear Lane, Urono, MN 55356 <br /> n WELL setbacks: 20'to pressure tested sewer line (5 psi for 15 min) <br /> 50'to everything 100'to dispersal area with shallow well <br /> PROPERTY LINES setback: 10'to everything <br /> Road setback: outer ditch, or 33'from center of township road, or 65'from center of cnty road <br /> LAKE/BLUFF setback: 20'for bluff. Lakes: GD_, RD_, NE . Protected Protected wetland . <br /> Building <br /> Building setbacks: 10'for everything, 20'for dispersal area. <br /> WATER LINE under pressure se 10'to bed,tank a sewer line. (else sewer line > 12"below) <br /> n Sewer line a baffle connection (no 90's, 3'between 45's, slope min 1"in 8', max 2"in 8') <br /> (no depth req's, clean out every 100', Sch 40 D2665 or F891) <br /> n Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br /> mfg 2250 gallons none <br /> Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br /> No effluent filter 8 alarm <br /> Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br /> mfg 1000 gallons <br /> n dose pump 29 gpm 23 head VERIFY PUMP CURVE 5.7 min ON 9 hr OFF <br /> n float setting drop 4.9 inches at 34.0 gpi "DESIGNED" 3.5 inches approx float tether length <br /> 166.0 gal dose divided by gpi "INSTALLED"= inches float drop (field corrected <br /> LABEL pump requirements and drawdown on riser or panel <br /> Cam lock reachable from grade- 30"max. J-hook weep hole. Supply line access (no hard 90's) <br /> supply pipe sloped 1/8"+, supported by sch40 sleeve, and buried 6"+. <br /> splice box / control panel / electrical connections <br /> flow measurement: CT, ETM, time dosed, home water meter <br /> mound absorption area rough up <br /> mound rock dimensions 10.0 X 50.0 <br /> Sand lift depth 16 inches. (Jar test : 2"sand leaves< 1/8"silt after 30 min) <br /> nAbsorption Sand beyond rock 0.0 upslope 5.0 downslope <br /> Bermed topsoil beyond rockbed 10 upslope 16 sideslope 22 downslope <br /> cover depth of 12-18"+ VERIFY <br /> 3 laterals (1-2'from edge of rock) <br /> 2.00 inch pipe size <br /> 3.0 ft lateral spacing <br /> 7/32 inch perforations <br /> 3.0 ft perforation spacing <br /> Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br /> clean outs (no hard 90's) <br /> 4"inspection pipe to bottom of rock, anchored VERIFY <br /> Abandon existing system - if necessary Re-use existing tank certification <br /> monitoring plan and type <br /> well abandonment form - if necessary <br />
The URL can be used to link to this page
Your browser does not support the video tag.