Laserfiche WebLink
10/15/2009 16: 15 9528733112 PAGE 04/05 <br /> Parcefinumber: - System status:ex Compliant ❑ Noncompliant <br /> (as determined by this form) <br /> Soil Separation Compliance and Other Compliance <br /> Compliance Issue #3 of 4 <br /> Date of observation: Ai l'-I _ Reason for observation: 131[This information on this fo doe not expire, <br /> Compliance questions/criteria: (Required) Verification Method**: (Optional) <br /> „-(Check the appropriate box) (Check the appropriate box) <br /> For systems built prior to April 1, 1996, and not Sk Conducted soil observation(s) (attach boring logs) <br /> located in Shoreland or Wellhead Protection <br /> Area or not serving a food, beverage or ❑ Two previous verifications (attach boring logs) <br /> lodging establishment: ❑ Other: 1�,4 <br /> Does the system have at least a two-foot .1 _ Z la 1 L1/6 <br /> ' <br /> vertical separation distance from periodically Q i r <br /> saturated soil or bedrock? ___ X Yes 0 No NO 111 <br /> For non-performancet systems built April .1, fit 0 Vt f 4 S r\ <br /> I <br /> 1996, or later or for non-performance systems S <br /> located in Shoreland or Wellhead Protection Soil observation does not expirerevious observations <br /> Areas or serving a food, beverage or lodging by two independent parties are sufficient, unless site <br /> establishment: conditions have been altered, <br /> Does the system have a three-foot vertical <br /> separation distance from periodically saturated <br /> soil or bedrock?' [] Yes ❑ No <br /> For reduced separation distance systems (i.e., <br /> "performance"systems under old 7080.0179 or ' May be reduced by up to 15 percent if allowed in focal <br /> Type IV or V system under new 7080. 2350 or ordinance, <br /> 7080.2400): ""No standard protocol exists. This list is not exhaustive, <br /> Does the system meet the designed vertical in sequential order, nor does it indicate which <br /> separation distance from periodically saturated combinations are necessary to make this <br /> soil or bedrock?' ❑ Yes ❑ No determination. <br /> Any"no"answer indicates that the system Is failing to protect <br /> ground water. <br /> Certification <br /> This form is to be completed and attached to the Summary Form of the Minnesota Pollution Control Agency's (MPCA) Compliance <br /> Inspection Form for Existing Subsurface Sewage Treatment Systems. Observations, interpretations, and conclusions must be <br /> completed by an inspector or designer. Completed form must be submitted to the local unit of government within 15 days. <br /> Property owner name(s): G r_c� ` s U -in m ps o .--.. <br /> Property address: '2-e p w r LI C'PJ no.�_ Irl _ —__-• <br /> Property owner's address(if different)! <br /> County: l h.&p l ' Phone: <br /> I hereby certify that I personally made the observations, interpretations, and conclusions reported on this form and that they are <br /> correct. <br /> Name: (1 a\ur-\6 Certification number: P-.1(()_6' <br /> �((Q ' <br /> Business license name and number. SLL.2L tun 6 S.('wL2,S-.._..w� L -- or <br /> Name of local unit of gov VL L�� <br /> Signature: _ Date: _IQ - --__— <br /> wq•wwists4-31 Compliance inspection Form for xlsting SSTS <br /> ailing <br />