My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1987 - Septiic System
Orono
>
Property Files
>
Street Address
>
W
>
Wear Circle
>
2845 Wear Circle- 33-118-23-34-0009
>
Septic
>
1987 - Septiic System
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:50:47 PM
Creation date
1/17/2020 9:02:49 AM
Metadata
Fields
Template:
x Address Old
House Number
2845
Street Name
Wear
Street Type
Circle
Address
2845 Wear Circle
Document Type
Septic
PIN
3311823340009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PIGGY BACK PLUG IN WEATHER ALARM WIRE DROP BOX <br /> PROOF ENCLOSURE-OR LOCATE FROSTPROOFI NG THE ,, Y 4 <br /> IN HOUSE BASEMENT MANHOLE COVER SECURED p 12• SOIL COVER <br /> POWER SUPPLY------"0 `TO PREVENT UNAUTHORIZED DISCHARGE PIPE __'',• j �,,, <br /> CONTROL WIRE ) ,ENTRY <br /> (, PLACE A ROCK ENVELOPE , '�a 2'�z"DIA ROCK <br /> VY PUMP POWER CORD @- y + tI DRAIN TILE OR RIGID <br /> 24•MANHOLE AROUND DISCHARGE3PIPE. I FROM PUMP PERFORATED PLASTIC PIPE <br /> ROCK SHOULD BE /4 TO 2 /z 3' MIN. FROM BOTTOM OF TRENCH TO <br /> ��`�'"` • INCHES IN DIAMETER, WITH <br /> FROM . I + WATER TABLE OR CLAY OR ROCK <br /> UNION OR OTHER NO SAND. COVER WITH A 2 V. LAYER <br /> SEP IC ALARM FLOAT ON SEPARATE FAIT ING DISCONNECTUICK <br /> TANK INCH THICK SHEET OF <br /> ELECTRICAL CIRCUIT EXPANDED POLYSTYRENE. <br /> RESERVE CAPACITY WHEREVER POSSIBLE MAIN- <br /> AFTER ALARM SOUNDS TO 5O1L <br /> TREATMENT TAIN A GRASS COVER OVER SOIL TREATMENT AREAS FOR TYPE I HOMES <br /> AREA TOP OF TRENCH AND ALLOW <br /> _-_ START LEVEL 9— 1/4 WEEPHOLE FOR SNOW TO REMAIN IN PLACE. REQUIRED SOIL TREATMENT AREA <br /> 3•] ‘ DRAINBACK;OR WHEN SNOW COVER IS LIGHT, IN SQUARE FEET PER BEDROOM <br /> _ CHECK VALVE MAY <br /> SHUT-OFF LEVEL • - BE INSTALLED IF PLACE A 6 INCH HAY OR PERCOLATION <br /> S—— PIPE TO TREATMENT TRENCHES <br /> r AREA IS FROST STRAW LAYER ON GROUND • RATE IN <br /> 12•-18•MINIMUM DEPTH_ PROOF ABOVE PIPE. INCH MINUTES PER SEEPAGE DEPTH OF ROCK BELOW <br /> �OOQ� BEDS DISTRIBUTION PIPE, IN INCHES <br /> LPUMPABLE CAPACITY WW , <br /> AT LEAST 75 GALLONSa��V� ;�<, 6 12 18 24 <br /> • <br /> BACKFILL `�� <br /> EXPANDED M'te FASTER b _ , . — — — <br /> PUMPING RATE SHOULD NOT EXCEED DROP BOX POLYSTYRENE ��ila THAN 0.1 <br /> OUTFLOW CAPACITY OR 45 GALLONS PER MINUTE DISCHARGE 0.1 TO 5 125 125 100 85 75 <br /> (2700 GALLONS PER HOUR). PIPE <br /> PUMP DISCHARGE HEAD MUST BE ADEQUATE TO ROCK 3/4"-2'/2" DIA. 6 TO 15 190 190 150 125 115 <br /> OVERCOME ELEVATION DIFFERENCE BETWEEN THE 16 TO 30 250 250 200 165 150 <br /> PUMP AND DISTRIBUTION BOX PLUS FRICTION LOSS <br /> IN DISCHARGE PIPE. 31 TO 45 300 300 240 200 I80 <br /> 46 TO 60 330 330 265 220 200 <br /> LIQUID CAPACITIES OF VERTICAL CIRCULAR TANKS SLOWER _ <br /> THAN 60b 1 <br /> INSIDE DIAMETER OF TANK GALLONS PER FOOT <br /> IN FEET OF DEPTH °SEWAGE FLOW • 150 GPD PER BEDROOM <br /> TO DETERMINE THE LIQUID bSPECIAL DESIGN SHOULD BE USED TO PROVIDE ADEQUATE <br /> 1.5 13.0 TREATMENT AND ABSORPTION OF EFFLUENT <br /> 2.0 23.5 CAPACITY OF ANY TANK, FIRST • <br /> DETERMINE THE SURFACE AREA , <br /> 2.5 37.0 OF THE LIQUID. MULTIPLY ' <br /> t <br /> 3.0 53.0 THIS VALUE BY 7.5 (GALLONS <br /> 4.0 94.0 PER CUBIC FOOT) TO DETER- RECOMMENDED AMOUNT OF EFFLUENT TO PUMP <br /> MINE THE TANK LIQUID PER CYCLE IS 25 PERCENT OF DAILY SEWAGE FLOW. <br /> 5.0 147.0 MINIMUM AMOUNT OF EFFLUENT TO PUMP PER <br /> 6.0 213.0 CAPACITY IN GALLONS PER CYCLE IS 75 GALLONS. <br /> FOOT OF DEPTH. <br /> FOR EXAMPLE, A CIRCULAR TANK WITH AN INSIDE <br /> DIAMETER OF 4 FEET HAS 94 GALLONS OF LIQUID <br /> CAPACITY PER FOOT OF DEPTH. <br /> TO PUMP 200 GALLONS PER CYCLE, THE PUMP <br /> CONTROL SWITCHES WOULD NEED TO BE SET 2.1 <br /> UNIVERSITY OF MINNESOTA <br /> (200/94) FEET APART. EXTENSION AGRICULTURAL ENGINEERING <br /> DSO, by REM <br /> �r <br /> I of I <br /> PUMPING STATION g'07 t24Nre <br /> R.. , /29'19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.