14. Materials used for the plumbing system shall comply with the standards set forth in the Minnesota Plumbing Code(see Minnesota Rules, <br /> part 4715.0420).Verify that the following pipe material requirements are met: <br /> a. The installation of the chlorinated polyvinyl chloride(CPVC)water distribution pipe must be in accordance with International Association <br /> of Plumbing and Mechanical Officials(IAPMO)Installation Standards 20-98(see Minnesota Rules,part 4715.0520). <br /> b. The hubless cast iron pipe used for the drain,waste,and vent piping must comply with ASTM Standard A888 or CISPI 301-05(see <br /> Minnesota Rules,part 4715.0570 through part 4715.0600). <br /> c. ABS plastic pipe used for the drain,waste,and vent system shall comply with ASTM Standard D2661 or F628(see Minnesota Rules, <br /> part 4715.0570 through part 4715.0600). ASTM Standard D2551 is not listed as an approved pipe material for drain,waste,and vent piping and must not <br /> be used. <br /> d. Plastic pipe must be installed in accordance with Minnesota Rules,part 4715.0580(F)and part 4715.0600. Above-grade horizontal runs of <br /> plastic waste and vent pipe cannot exceed 35 feet in total length. Above-grade vertical stacks constructed of plastic pipe may exceed 35 feet in total <br /> height only if an approved expansion joint is used. <br /> 15. The installation of cross-link polyethylene(PEX)tubing was specified for the water distribution system. If all of the following requirements cannot be <br /> met,a different material that complies with Minnesota Rules,part 4715.0520 must be used: <br /> a. The tubing system must comply with ASTM Standard F877 and F876. <br /> b. When installed as a system in accordance with ASTM Standard F877,the system tubing and fittings must be of the same manufacturer. <br /> c. When other fittings are used with ASTM Standard F877 and F876 tubing,the fittings must comply and be marked with ASTM <br /> Standard F1807,F1960,F2080,F2098-01,or F2159. In addition,the tubing must be marked to indicate the fitting standard and the corresponding tubing <br /> standard(e.g.ASTM F877/F876/F1960,F877/F876/F1807,etc.). <br /> d. The system must be installed by a factory trained installer of the particular PEX system to be installed. Certain manufacturers require <br /> installation by licensed plumbers who have been trained to install their material. <br /> e. All persons installing PEX materials shall have a card on their possession documenting completion of training by the manufacturer or his <br /> agent for the material to be installed. <br /> f. The tubing and fittings must be marked as required by the applicable standard specification and with the appropriate ASTM designations by <br /> the manufacturer. <br /> g. The installation must be in accordance with the manufacturer's installation instructions. <br /> NOTE(S): <br /> 1. The scope of this project consists of the remodel of a grocery store.The plumbing includes the following: <br /> a. Two restrooms and a break room sink. <br /> b. Produce-A prep sink,a floor drain,a trench drain,and a hand sink.A capped and valved 1/2-inch cold water pipe will be provided for <br /> future connection to a filter or other equipment.No backflow protection will be provided on the pipe at this time. <br /> c. Meat-A three-compartment sink,a tell-tale floor drain,a trench drain,and a hand sink. <br /> d. Kitchen-A prep sink,a three-compartment sink,three tell-tale drains,a trench drain,two floor drains,a dishwasher,and two hand sinks.A <br /> capped and valved 1/2-inch cold water pipe will be provided for future connection to a coffee maker.No backflow protection will be provided on the pipe <br /> at this time. <br /> e. Dairy-A floor drain and a trench drain outside of the dairy cooler. <br /> f. Service/Deli-A hand sink and a capped and valved 1/2-inch cold water pipe will be provided for future connection to a coffee maker.No <br /> 3 <br /> A 3 k) % L �oiss- <br />