My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2010 - 00213 - sprinkler system
Orono
>
Property Files
>
Street Address
>
W
>
Wayzata Boulevard West
>
2380 Wayzata Boulevard West - Harvest Moon Co-op
>
Permits/Inspections
>
2010 - 00213 - sprinkler system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2023 7:19:48 AM
Creation date
1/15/2020 2:33:49 PM
Metadata
Fields
ProcessedPID
True
Tags
No PIN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> General Installation Instructions the bulb supporting cup and the wrenching boss. Do not <br /> In steel pipe, the Model F3QR Dry Sprinklers must be replace this wax with a substitute substance.An Alternate <br /> installed only in standard (ANSI B 16.3 class 150 and - substance may interfere with proper operation of the <br /> ANSI B 16.4 class 125) pipe tees even at branch line sprinkler. Do not clean sprinklers with soap and water, <br /> ends. For these and CPVC* Tees, the dry sprinkler ammonia or any other cleaning fluids. Remove dust by <br /> should be installed and confirmed to have appropriate using a soft brush or gently vacuuming. Remove any <br /> protrusion into the tee in accordance with the figures on sprinkler which has been painted (other than factory <br /> pages 2 & 3. Dry sprinklers must not be installed into applied) or damaged in any way. A stock of spare <br /> elbows and into pipe couplings located on drop nipples sprinklers should be maintained to allow quick <br /> to the sprinklers. The "A' dimension of a dry sprinkler, replacement of damaged or operated sprinklers. Prior to <br /> which extends into a freezer from a wet pipe system, installation, sprinklers should be maintained in the original <br /> should be selected to provide at least 14" (356mm) cartons and packaging until used to minimize the potential <br /> between the freezer's outside wall or ceiling and the wet for damage to sprinklers that would cause improper <br /> pipe line. When the temperature inside the freezer will be operation or non-operation. <br /> below-30°F(-35°C), increase the 14" to 20" (509mm). <br /> 1. Cut the specified size hole (see illustrations) for the <br /> sprinkler in the ceiling directly in line with the tee. *Spears CPVC sprinkler adapter tees(with steel thread <br /> 2. Apply pipe joint compound to the 1" (25mm) pipe insert) can only be used with horizontal sidewall <br /> threads and install sprinkler using the Model G3 or sprinklers which do not require protrusion into tees to <br /> G3 R/C Sprinkler Wrench as specified. prevent ice or debris blockage of sprinkler inlets. These <br /> 3.Install the push-on escutcheon or coverplate. CPVC tees do not permit sufficient sprinkler inlet <br /> P protrusion as required for pendent installation. <br /> Note: Installation of the Model F3QR Sprinklers in <br /> copper pipe systems is not recommended, <br /> as this may reduce the life expectancy of the <br /> sprinklers. <br /> Model F3QR Concealed and Recessed <br /> Installation Instructions <br /> • The Model G3 R/C wrench(Fig. 1)is designed to locate <br /> on the wrenching pads of the recessed sprinkler while <br /> centering in the cup. A standard 1/2" drive ratchet may <br /> be used to drive this wrench. Figures 1 and 2 show <br /> sequentially the insertion of the wrench.First the wrench, <br /> with its jaws above the sprinkler deflector, is moved <br /> laterally until centered with the cup. Then raise the <br /> wrench inside of the cup until its jaws engage the <br /> sprinkler's square wrenching pads (Fig. 3). To remove <br /> the wrench,follow this procedure in reverse order. Care <br /> should be taken to avoid striking the deflector, with the <br /> wrench. <br /> • Model G3 Wrench (Fig. 4) is used for installation of <br /> Pendent and Horizontal Sidewall sprinklers. <br /> • Glass bulb sprinklers have orange bulb protectors to <br /> minimize bulb damage during shipping, handling and <br /> installation.REMOVE THIS PROTECTION AT THE TIME <br /> THE SPRINKLER SYSTEM IS PLACED IN SERVICE <br /> FOR FIRE PROTECTION. Removal of the protectors <br /> before this time may leave the bulb vulnerable to <br /> damage. RASCO wrenches are designed to install <br /> sprinklers when covers are in place. REMOVE <br /> PROTECTORS BY UNDOING THE CLASP BY HAND. <br /> DO NOT USE TOOLS TO REMOVE THE <br /> PROTECTORS. <br /> Maintenance <br /> The Model F3QR Quick Response Dry Sprinklers should <br /> be inspected quarterly and the sprinkler system <br /> maintained in accordance with NFPA 25. Do not remove <br /> the factory applied thermally sensitive wax fillet between <br /> 5. <br />
The URL can be used to link to this page
Your browser does not support the video tag.