My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
04-16-2018 Planning Commission Packet
Orono
>
Planning Commission
>
2018
>
04-16-2018 Planning Commission Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 3:54:11 PM
Creation date
1/14/2020 3:27:06 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
268
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
o 2018 Westwood Professional Services, Inc. <br />PRUNE OUT MISDIRECTED BRANCHES. <br />PROVIDE ONE CENTRAL LEADER. <br />GUYING AND STAKING, AS REQUIRED, <br />FOR ONE (1) YEAR ON ALL <br />DECIDUOUS AND CONIFEROUS TREES: <br />TOP STAKES 5' ABOVE GROUND <br />�e <br />(MAX.) OR TO FIRST BRANCH. <br />o <br />BOTTOM OF STAKE 3' (MIN.) <br />°` ga BELOW GROUND. STAKING POSTS <br />TO BE 2"X2" STAINED WOOD OR <br />PAINTED STEEL DELINEATOR <br />POSTS. PLACE 3 POSTS <br />a gip° ao�a EQUIDISTANT AROUND AND <br />aP a �a OUTSIDE ROOT BALL. SEC URE <br />° <br />TREE TO POSTS WITH 16" LONG <br />POLYPROPYLENE OR <br />POLYETHYLENE, 40 MIL., 1.5" <br />WIDE STRAP. <br />PLACE MULCH, DEPTH AS SPECIFIED, <br />II 2X BALI I OVER PLANT PITS — DO NOT PILE <br />DIAMETER AGAINST TRUNK. <br />3" DEEP WATERING BASIN. <br />_ _FORM <br />III—III III =BACKFILL PLANT PIT WITH SPECIFIED <br />I I' I I II111- BACKFILL solL. <br />I II I II <br />SCARIFY SIDES AND BOTTOM OF HOLE. <br />III III- REFER TO AMERICAN STANDARD FOR <br />— <br />=III—i III— NURSERY STOCK FOR MINIMUM BALL <br />SIZE. ROOT FLARE TO BE PLANTED <br />AT OR NEAR FINISHED GROUNDLINE. <br />SET ROOT BALL ON UNDISTURBED <br />SUBSOIL OR COMPACTED SOIL MOUND <br />MATCHING TREES NATURAL <br />GROUNDLINE WITH FINISHED SITE <br />GRADE. N.T.S. <br />Westwood <br />DECIDUOUS TREE <br />C1 <br />LA28 <br />/ C-*.- -- - 'A -4-L, —, 1AI-4.----' <br />PLANTING <br />PRUNE OUT MISDIRECTED <br />BRANCHES. PROVIDE ONE <br />CENTRAL LEADER. <br />GUYING AND STAKING AS REQUIRED, <br />FOR ONE (1) YEAR ON ALL <br />DECIDUOUS AND CONIFEROUS TREES: <br />TOP STAKES 5' ABOVE GROUND <br />(MAX.) OR TO FIRST BRANCH. <br />BOTTOM OF STAKE 3' (MIN.) <br />BELOW GROUND. STAKING <br />POSTS TO BE 2"X2" STAINED <br />d� WOOD OR PAINTED STEEL <br />DELINEATOR POSTS. PLACE 3 <br />POSTS EQUIDISTANT AROUND <br />AND OUTSIDE ROOT BALL. <br />SECURE TREE TO POSTS WITH <br />16" LONG POLYPROPYLENE OR <br />POLYETHYLENE, 40 MIL., 1.5" <br />WIDE STRAP. <br />PLACE MULCH, DEPTH AS <br />° ! ° SPECIFIED, OVER PLANT PITS — <br />DO NOT PILE AGAINST TRUNK. <br />2 BA <br />DIA FORM 3" DEEP WATERING BASIN. <br />BACKFILL PLANT PIT WITH <br />— SPECIFIED BACKFILL SOIL. <br />SCARIFY SIDES AND BOTTOM OF <br />HOLE. <br />REFER TO AMERICAN STANDARD <br />III -III— �I-I1— FOR NURSERY STOCK FOR <br />MINIMUM BALL SIZE. ROOT <br />FLARE TO BE PLANTED AT OR <br />NEAR FINISHED GROUNDLINE. <br />SET ROOT BALL ON UNDISTURBED <br />SUBSOIL OR COMPACTED SOIL <br />MOUND MATCHING TREES NATURAL <br />GROUNDLINE WITH FINISHED SITE <br />GRADE. N.T.S. <br />Westwood <br />EVERGREEN TREE <br />LA29 <br />PLANTING <br />REMOVE CONTAINER, SET SOIL MASS <br />ON COMPACTED SOIL MOUND <br />MATCHING SHRUBS NATURAL <br />o <br />® GROUNDLINE WITH FINISHED GRADE. <br />o p ALL PLANTING BEDS SHALL RECEIVE <br />4" OF SPECIFIED MULCH AND WEED <br />BARRIER FABRIC. <br />o EDGE ALL PLANTING BEDS WITH <br />SPECIFIED EDGER WHERE ADJACENT <br />TO LAWN AREAS. <br />III III 111HIM F <br />—I —— = — SCARIFY SIDES AND BOTTOM OF <br />. — —I - <br />HOLE. <br />1- <br />I I'' I—III— <br />—III—III_ <br />—III -1-11' BACKFILL PLANT PIT WITH SPECIFIED <br />BACKFILL SOIL. <br />N.T.S. <br />Westwood <br />SHRUB PLANTING <br />LA27 <br />Phone (952) 937-5150 7699 Anagram Drive <br />Fax (952) 937-5822 Eden Prairie, MN 55344 <br />Toll Free (888) 937-5150 westwoodps.com <br />Westwood Professional Services, Inc. <br />STO <br />ST <br />WA T WA T WA r <br />STo STO <br />�sro� <br />4 <br />Redwing Viburnum / Viburnum trilobum 'J.N. Select' <br />#5 <br />CONT. <br />Final <br />Plant <br />Schedule <br />- <br />CODE <br />QTY. <br />COMMON/BOTANICAL NAME SIZE SPACING O.C. <br />o 0 <br />4'-0" <br />Ruby Stella Daylily / Hemerocallis 'Ruby Stella' <br />O.C. <br />7 <br />TEA <br />22 <br />Techny Arborvitae / Thuja occidentalis 'Techny' #7 CONT. 5'-0" O.C. <br />#5 <br />TAY <br />64 <br />Taunton Yew / Taxus x media 'Taunton' #7 CONT. 4'-0" O.C. <br />—SAN— —SAN _ SAN <br />SAN <br />—WAT WA T— WAr WAT WA WA WA WAT <br />a a <br />s�o �——a— <br />° STO ST <br />° ° a sro <br />a <br />a 4 <br />sro <br />RWV <br />4 <br />Redwing Viburnum / Viburnum trilobum 'J.N. Select' <br />#5 <br />CONT. <br />6'-0" <br />O.C. <br />ABH <br />59 <br />Incrediball Hydragea / <br />Hydrangea arborescens 'Abetwo' <br />#5 <br />CONT. <br />4'-0" <br />Ruby Stella Daylily / Hemerocallis 'Ruby Stella' <br />O.C. <br />18" <br />20 <br />Summer Wine Ninebark <br />/ Physocarpus opulifolius 'Seward' <br />#5 <br />CONT. <br />4'-0" <br />O.C. <br />O.C. <br />— SWN <br />SA) LDN <br />9 <br />Little Devil Ninebark / <br />Physocarpus opulifolius 'Donna May' <br />#5 <br />CONT. <br />3'-0" <br />O.C. <br />A U10 <br />C1 <br />A- 4-L,,-, , \AI -4.---- <br />/ C-*.- -- - 'A -4-L, —, 1AI-4.----' <br />11C <br />/InAI-r <br />" <br />n" <br />n r, <br />KFG <br />131 <br />Karl Forester Grass / Calamagrostis x acutiflora 'Karl Forester' <br />#1 CONT. <br />36" <br />O.C. <br />LBS <br />49 <br />Blue Heaven Little Bluestem / Schizachyrium scoparium 'Minnblue A' <br />#1 CONT. <br />24" <br />O.C. <br />SDO <br />191 <br />Ruby Stella Daylily / Hemerocallis 'Ruby Stella' <br />#1 CONT. <br />18" <br />O.C. <br />AFS <br />66 <br />Autumn Fire Sedum / Sedum x 'Autumn Fire' <br />#1 CONT. <br />18" <br />O.C. <br />102� NOTE: QUANTITIES ON PLAN SUPERSEDE LIST QUANTITIES IN THE EVENT OF A DISCREPANCY. <br />I• I• .I . <br />16 FS I I . + +\STo a \ \ <br />d 'STO <br />D 29 SDO ►► — — <br />— G�--- — -- — — — — — 22 3 TAY 7 AWS ` ►►� , \\ Sro � <br />8 KFG 3 TAY ► ° <br />a 4 A ►. °° \ <br />5 T Y <br />NIN tld i ON 00000 <br />5 BH <br />' I 4 TEA <br />+ + I T + <br />I I+ I a T I+ 5 TAY 2 ABH \ + <br />I I 3 TAY i d ti d° i \ <br />I I <br />+ i �o� 15 LBS 15 LBS <br />CD <br />5 ABH 2 ABH I <br />7 TAY i I i a `$ 17 AFS I I 17 AFS i` <br />. I <br />ji 106 5 ABH i 5 AWS 41 21 SDO i 21 SDO ° a i 2 TEA ��2� <br />I <br />/I I 8KFG 8KFG <br />I i0 I I 11 AWS ° ° m °a ° da ° d" 1 23 I + + <br />+I o■ °■ I` <br />3 TAY (I �--- —--- I I O I + <br />.O 0•' <br />° <br />4 KFG x x x x 00 000 l I ;. O I 7 AWS 7 AWS I 0' I 10e <br />9 FG I — —� i i• 0 O I <br />OI I I <br />J J / ;\_ I 4 RWV 5 TAY i — ------ a° <br />---I <br />ABH I 2 TEA 8 KFG 3 TEA ------------ � <br />+ � �-- � 10 AB OOOOQ 00� — — ---- o— I I d � <br />6 T�' I I a <br />+� I d <br />+ +I I <br />I I I <br />3 TEA + I <br />5 T 'Y i 7 AWS 5 TAY I la <br />2 TAY 2 TEA 8 KFG I I ° <br />8 KFG I I <br />I <br />—1025 -- O <br />WN I 102 / 1 7 AWS 0' <br />(� O I d <br />I 1 0 <br />I / / 6 WN i 0 --- ° <br />\ / N 3 ABH I ° <br />+ as <br />10e L 2 TEA 42 SDO da g <br />5 T to i 2 TEA 5 ABH 8 KFG 4 TAY 5 SWN <br />I I ► ►1 I � <br />I 9 LDN 2 ABH i <br />5 KING ' �A' <br />I \ / 8 KFG � ° <br />O5 ABH <br />I <br />I <br />I4 VN <br />3 T Y <br />1 <br />sro <br />+ _ r <br />— ` • / ° ° a d a d ----- -+ -+ - + ------ / O Td Oda. <br />� 7 I <br />\ � l lo�� •� — �4• a a °� ° ad°° a ° a d d 0° �16 FG <br />4, d a ° a ° d a d I a ° ° <br />A d a ° d° <br />d � <br />I ARKIN <br />33 KFG 1030 <br />— — — — — — — — — — — — — — — — — <br />— — — — — — — — — — — — — — — — — — — — — <br />S S To <br />sro sro <br />1027 <br />026 <br />X X X X X X X X �,;� <br />X + <br />— GAS GAS GAS qS qS X <br />GAS <br />POH POH POH <br />� POH POH <br />27 O <br />O ("�� i4 <br />I hereby certify that this plan was prepared by me or under my RevlBiOne <br />direct supervision and that I am a duly licensed PROFESSIONAL <br />LANDSCAPE ARCHITECT under the laws of the State of Minnesota. 08/07/17 — City Comments <br />03/20/18 — Final Development Approval Plans <br />Nicholas Meyer, PLA <br />Dab~ 03/20/18 Licenae Na 53774 <br />GA GAS GA S <br />POH Po <br />A <br />DedxnedL N7U Prepared for: <br />Checked- NTM <br />Drawn: NTM <br />Record Drawing by/date: <br />GAS GAS <br />H POH <br />REM <br />.�1'• <br />GAS GAS <br />POH po� <br />POH,..� \ <br />• • 7 -, n OH <br />Orono <br />• - • <br />Apex HLLC <br />2110 Lyndale Avenue South Suite C <br />Minneapolis, MN 55405 <br />Housing <br />Orono, Minnesota <br />0' 20' 40' 60' <br />Call 48 Hours before digging: <br />811 or cal1811.com <br />Common Ground Alliance 0011740PLP01.dwg <br />Date: 06/19/17 Sheet- 11 of 13 <br />Landscape Plan <br />
The URL can be used to link to this page
Your browser does not support the video tag.