Laserfiche WebLink
o. o <br /> CiTy0f ORONO <br /> Vs" "a'I titi Municipal Offices <br /> .1 r"I "' �iyG Street Address: Mailing Address: <br /> 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: �r� �)v r AS 3Q�.� L� <br /> Address:_ V_ y � <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every t<vo years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): <br /> 1 "CODE SYSTEM" An ISTS which meets all the location,design and construction standards ofthe current Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and construction standards of the current Orono Municipal <br /> Code but does meet the three foot separation requirement,and which is not failing or an imminent threat to public health or safety. <br /> O "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any reason;and <br /> any ISTS with less than three feet of unsaturated soil or sand between the distribution device and the limiting Soil characteristics, <br /> TANK CONDITION <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> OTank must be pumped out this year (city code requires tanks to be pumped out every 3 years. Tank was last pumped <br /> 7 Solids accumulation in tanks is at a critical a aitical level. Tanks should be pumped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank at next pumpout If tanks <br /> have not been pumped out within the last three years,they should be pumped out now. <br /> 10 Inspection pipe is located directly over tank bade(does not give accurate measurement of solids accumulation). If tanks have not been pumped <br /> out within the last three years,they should be pumped out now. <br /> QAAREIELD CONDITION 11-14 <br /> I 1 Drainfield is dry,no surfacing evident <br /> 12 Some evidence of surfacing,not critical yet <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately.Repairs must be <br /> completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> COMI4ENTS: Sty r\5 qct Ao C 0 cn--v- r)ve- -1-0 I 6ACK dl 3 4t,r Se mj-:o,\ <br /> Id.31 -a.01a• <br /> Date of Inspection W <br /> Septic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does not guarantee <br /> or certify that an existing system will continue to function properly,but is merely an opinion of the adequacy of the system under current conditions hzeed n"the avaitahte <br />