My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018 - 00095 - fire alarm
Orono
>
Property Files
>
Street Address
>
W
>
Wayzata Boulevard West
>
2190 Wayzata Boulevard West - 34-118-23-21-0033
>
Permits/Inspections
>
2018 - 00095 - fire alarm
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:55:33 PM
Creation date
1/13/2020 1:49:28 PM
Metadata
Fields
Template:
x Address Old
House Number
2190
Street Name
Wayzata
Street Type
Boulevard
Street Direction
West
Address
2190 Wayzata Boulevard West
Document Type
Permits/Inspections
PIN
3411823210033
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(►3 Smoke Detector Specifications <br /> Architectural/Engineering Specifications <br /> Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The <br /> detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F <br /> (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster <br /> ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the <br /> base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The <br /> detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- <br /> color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used <br /> in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel <br /> and shall provide a loop testing capability to verify the circuit without testing each detector individually. <br /> Electrical Specifications <br /> Operating Voltage Nominal: 12/24 V non-polarized <br /> Minimum: 8.5 V <br /> Maximum:35 V <br /> Maximum Ripple Voltage 30%peak to peak of applied voltage <br /> Standby Current 2-wire:50 pA maximum average;4-wire:50 pA maximum average <br /> Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24V <br /> Peak Standby Current 2-wire:100 pA;4-wire:n/a <br /> Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30V AC/DC <br /> Physical Specifications <br /> Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height <br /> Weight 6.3 oz(178 g) <br /> Operating Temperature Range 2W-B and 4W-B:32°F to 120°F(0°C to 49°C);2WT-B and 4WT-B:32°F to 100°F(0°C to 37.8°C) <br /> Operating Humidity Range 0 to 95%RH non-condensing <br /> Thermal Sensor 135°F(57.2°C)fixed <br /> Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C) <br /> Sensitivity 2.5%/ft nominal <br /> Input Terminals 14 to 22 AWG <br /> Mounting 31/2-inch octagonal back box <br /> 4-inch octagonal back box <br /> Single-gang back box <br /> 4-inch square back box with a plaster ring <br /> Direct mount to ceiling <br /> LED Modes Power-Up Sequence for LED Indication <br /> LED Mode Green LED Red LED Condition Duration <br /> Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds <br /> Normal(standby) Blink every 5 seconds off <br /> Out of sensitivity off Blink every 5 seconds <br /> Freeze trouble off Blink every 10 seconds <br /> Alarm off Solid <br /> Ordering Information <br /> Model Thermal Wiring Alarm Current <br /> 2W-B No 2-wire 130 mA max.limited by control panel <br /> 2WT-B Yes 2-wire 130 mA max.limited by control panel <br /> 4W-B No 4-wire 20 mA @ 12 V,23 mA @ 24 V <br /> 4WT-B Yes 4-wire 20mA@12V,23mA@24V <br /> Accessories <br /> 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool <br /> SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter <br /> .SYSTEM 02009 System Sensor. <br /> �Y 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications whject to change without notice.M.t systemsensormm for <br /> SENSOR Phone:800-SENSOR2•Fax:630-377-6495 current product information,induding the latest version of this data sheet <br /> A05-0318-007.6/09.82169 <br />
The URL can be used to link to this page
Your browser does not support the video tag.