<br /> ARI capacity ratings (cont) carrier
<br /> . a
<br /> HEATING CAPACITIES AND EFFICIENCIES - 48TJ004-014
<br /> HEATING INPUTTEMPERATURE STEADY-STATE CALIFORNIA
<br /> (Btuh) OUTPUT CAPACITY AFUE EFFICIENCY SEASONAL
<br /> UNIT 48TJ StagRI
<br /> 2/Stage 1 (Btuh) RISE (%) (%) EFFICIENCY
<br /> (%)
<br /> 004 -/ 72,000 59,200 25-55 80.0 80.0 77.2
<br /> F004 115,000/ 82,000 92,000 55-85 80.0 80.0 76.7
<br /> 11"141111.- D005 -/ 72,000 59,200 25-55 80.0 80.0 77.2
<br /> 005 -/115,000 92,000 35-65 80.0 80.0 77.1
<br /> F005 150,000/120,000 120,000 50-80 80.0 80.0 76.9
<br />®)bD006 -/ 72,000 59,200 25-55 80.0 80.0 77.2
<br /> c006 -/115,000 92,000 35-65 80.0 80.0 77.1
<br /> F006 150,000/120,000 120,000 50-80 80.0 80.0 76.9
<br /> 1111111007 -/ 72,000 59,200 25-55 80.0 80.0 77.2
<br /> 007 -/115,000 92,000 35-65 80.0 80.0 77.1
<br /> F007 150,000/120,000 120,000 50-80 80.0 80.0 76.9
<br /> D008 -/125,000 100,000 20-50 80.0 80.0 75.8
<br /> E008 180,000/120,000 144,000 35-05 80.0 80.0 77.1
<br /> F008 224,000/180,000 179,200 45-75 80.0 80.0 77.1
<br /> D009 -/125,000 100,000 20-50 80.0 80,0 75.8
<br /> E009 180,000/120,000 144,000 35-65 80.0 80.0 77.1
<br /> F009 224,000/180,000 179,200 45-75 80.0 80.0 77.1
<br /> 0012 180,000/120,000 144,000' 35-65 80.0 80.0 77.1
<br /> E012 224,000/180,000 179,200 35-65 80.0 80.0 77.1
<br /> •
<br /> F012 250,000/200,000 200,000 40-70 80.0 80.0 76.4
<br /> 0014 224,000/180,000 179,200 35-65 80.0 80.0 77.1
<br /> E014 250,000/200,000 200,000 40-70 80.0 80.0 76.4
<br /> LEGEND
<br /> AFUE-Annual Fuel Utilization Efficiency
<br /> NOTE: NOx levels are 40 nanograms/joule with the accessory NOx reduction kit(sizes 004-014).
<br /> HEATING CAPACITIES AND EFFICIENCIES - 48TJ016-028
<br /> HEATING INPUTOUTPUT CAPACITY TEMPERATURE STEADY-STATE MINIMUM
<br /> UNIT 48TJ (Btuh) (Btuh) RISE EFFICIENCY HEATING
<br /> Stage 2/Stage 1* (F) (%) CFM
<br /> D016 230,000/172,000 186,000 15-45 81.0 3800
<br /> F016 300,000/225,000 243,000 30-60 81.0 3800
<br /> 0020 275,000/206,000 223,000 15-45 81.0 4750
<br /> F020 360,000/270,500 292,000 20-50 81:0 5450
<br /> 0024 275,000/206,000 223,000 15-45 81.0 4750
<br /> F024 360,000/270,000 292,000 20-50 81.0 5450
<br /> 0028 275,000/206,000 223,000 15-45 81.0 4750
<br /> F028 360,000/270,000 292,000 20-50 81.0 5450
<br /> 'All units are 2-stage heat.
<br /> NOTE: Minimum allowable temperature of mixed-air entering the heat exchanger during first-stage
<br /> heating is 45 F.There is no minimum mixed-air temperature limitation during second-stage heating.
<br /> c
<br />
|