CIVIE CONSULTANTS, INC. GME Job No. 9,;20-74 <br /> Geotechnical • Materials • Environmental Job Name�;� ` otic` <br /> Minneapolis, MN Crosby, MN Menomonie, WI <br /> (763) 559-1859 (218) 546-6371 (715) 235-8844 <br /> International Falls, MN Ft. McCoy/LaCrosse, WI Willmar, MN ,� <br /> (21 8) 283-2958 (608) 785-1915 (320) 231-3941 Location (-"147 <br /> Duluth, MN Janesville, WI Chicago, IL <br /> (218) 722-4323 (608) 752-8050 (708) 430-1071 <br /> DAILY FIELD REPORT <br /> FIELD TESTING OF FRESH CONCRETE <br /> Tg G� <br /> \--(tuna., n, T n S TIME:_gaO__ AM/PM/DATE: da / \ /Ci, <br /> WEATHER: 3 • o <br /> • <br /> Location of <br /> Placement: c (.� S &&ceLQ (t ` c- C Uw rALL <br /> � F&'r <br /> Supplier: PQn 1.n c\ Mix Number Required 28 Day Strength 3,coc)J it u <br /> Specified Slump 53 — CI Mix plasticized? Yes No X Specified Air Content <br /> TEST CYL SLUMP AIR TEMPERATURE °F TIME TRUCK WATER C.Y./ <br /> # SET BEFORE AFTER CONTENT NUMBER ADDED C.C.Y. <br /> # MIX AIR SAMPLE <br /> PLASTICIZER FREQUENCY <br /> 2 (2)-3/i3 <br /> 4 <br /> 3 (_' -3 /1.3 <br /> 4 .ti.5 , le? —30 <br /> 5 <br /> 6 <br /> 7 <br /> 8 <br /> r s <br /> 9 <br /> 1 10 <br /> Samples cast by: GME Contractor X Number of cylinders cast per set 4 <br /> Samples cast in: 6" x 12" X 4" x 8" <br /> Cylinders were cured on site where? ��C1,5k,�e___, e..n,irhsoyr_ <br /> Method of Placement Via: Truck Chute Power Buggy Bucket Pump Truck <br /> \ � <br /> Schedule for testing of cylinders: __5�).—Q (S S V <br /> COMMENTS: <br /> Signed <br /> Date / / • <br /> Cylinders brought into GME Lab for curing and <br /> , <br /> testing / \A /____C) <br /> Signed / ��. C— , <br /> REV.4/00 <br />