_a R„S ' tyco Fire & /SimplexGrinnell <br /> Security <br /> ,s�^^�� / l DRY PIPE VALVE TRIP TEST REPORT Y'1,4:1::°? <br /> / <br /> FOR OR C7/( 0 RI`Oa Pc /� INSPECTION NO. 1 () , °? <br /> STREET 90 �U k.j Lv �G/7%!' &1?&ITY Off''• 0110' STATE /O� CONTRACT NO. <br /> DATE OF TRIP TEST "' .9- / INSPECTOR r7wZ-4/19 . DAY WORK NO. <br /> NOTE: BEFORE ANY DRY PIPE VALVE IS TRIP TESTED,THE WATER SUPPLY LINE TO IT SHOULD BE THOROUGHLY FLUSHED.THE TWO INCH DRAIN BELOW <br /> THE VALVE SHOULD BE OPENED WIDE, AND WATER AT FULL PRESSURE SHOULD BE DISCHARGED LONG ENOUGH TO CLEAR THE PIPE OF ANY <br /> ACCUMULATION OF SCALE OR FOREIGN MATERIAL. IF THERE IS A HYDRANT ON THE SUPPLY LINE,THIS HYDRANT SHOULD BE FLUSHED BEFORE <br /> THE TWO INCH DRAIN IS OPENED.THE DRIP VALVE ON THE DRY PIPE VALVE SHOULD BE CHECKED BEFORE TRIPPING THE DRY PIPE VALVE.TO.SEE <br /> THAT IT IS IN OPERATING CONDITION. <br /> DRY PIPE VALVES SYSTEM NO. ( ) SYSTEM NO. ( ) SYSTEM NO. ( ) SYSTEM NO. ( ) <br /> VALVE SERIAL NUMBER 'yi/' 13 <br /> MANUFACTURER(NAME) A9eL/4�1 <br /> �-r <br /> VALVE MODEL ).2 <br /> VALVE SIZE 9i,_ INCH INCH INCH INCH <br /> (LOCATION) li %, C <br /> CONTROLLING SPRINKLERS <br /> (NUMBER) . , --,___ W_._ (AP'ROX) ,, .. (APP,RQX) t(APPROX) _ (APPROX) <br /> DATE LAST TRIP TESTED? - <br /> DATE LAST OPERATED? i <br /> AIR c LBS LBS LBS LBS <br /> - PRESSURE BEFORE TEST <br /> WATER G LBS LBS LBS LBS <br /> SIZE AND LOCATION OF TEST VALVE /'' S <br /> WAS GATE VALVE BELOW DRY VALVE OPEN WIDE AT TEST? ` <br /> (IF NOT,HOW MANY TURNS?) Al�. <br /> AIR PRESSURE /d LBS LBS LBS LBS <br /> VALVE TRIPPED AT _ WATER PRESSURE /^/ LBS LBS LBS LBS <br /> TIME MIN if OSEC MIN SEC MIN SEC MIN SEC <br /> IF SYSTEM FLOODED,LIST TIME WATER <br /> REACHED TEST OPENING �JGI�MIN /'GTp MIN SEC MIN SEC MIN SEC <br /> ( a ( I` <br /> PERFORMANCE O <br /> INTERIOR OF BODY t F� 0 I <br /> MOVING PARTS 0 Jr <br /> VALVE CONDITION RUBBER FACING (�f/7 <br /> SEATS a/i <br /> RESET? /�S <br /> DID ALARMS OPERATE AT TRIP TEST? 4 c <br /> ALL LOW POINT DRAINS BLOWN OUT? '1 5 <br /> WATER CONTROL VALVE LEFT <br /> OPEN AND SEALED? /C"G' <br /> ALARM CONTROL VALVE LEFT / � <br /> OPEN AND SEALED? 1 <br /> QUICK OPENING DEVICES SYST4M NO. ( ) SYSTEM NO. ( ) SYSTEM NO. ( ) SYSTEM NO. ( ) <br /> DEVICE SERIAL NUMBER <br /> MANUFACTURER(NAME) <br /> TYPE AND MODEL /b/120, <br /> AIR PRESSURE IN UPPER CHAMBER LBS LBS LBS LBS <br /> QUICK OPENING DEVICE TRIPPED AT SEC LBS SEC LBS SEC LBS SEC LBS <br /> PERFORMANCE <br /> QUICK OPENING DEVICE LEFT IN SERVICE <br /> AND CONTROL OPEN AND SEALED? <br /> LIST ANY UNSATISFACTORY CONDITIONS: <br /> REMARKS <br />