CONCRETE STRENGTH REPORT <br /> GME Consultants, Inc. <br /> Project and Location: Orono Woods Senior Apartments. Orono. Minnesota �� 14000 21st Avenue North <br /> Architect/Engineer: Miller Hanson Westerbeck Berger, Inc. Minneapolis, MN 55447 <br /> General Contractor: Frana & Sons 1 �� Ph. (763)559-1859 <br /> Concrete Contractor: Hicks Concrete L'�►/ Fax(763)559-0720 <br /> Owner/Developer: Wedum Foundation <br /> GME Project Number: 9212-A <br /> CONCRETE SUPPLIER: Aggregate Industries ] PLANT: MIX CUMULATIVE QUANTITY YDS <br /> SPECIFIED <br /> MIX WAS NOT PLASTICIZED: SLUMP(inch): N/A SPECIFIED AIR CONTENT(%)• 4000 <br /> N/A REQUIRED STRENGTH AT 28 DAYS: psi <br /> DATE CAST SLUMP(inch) TEMPERATURE <br /> DATE BEFORE AFTER DATE AGE CYL WT. MAX LOAD(Ibs- <br /> SET NUMBER RECEIVED PLASTICIZER PLASTICIZER AIR% MIX e F) AIR f F) TIME TRUCK# TESTED COMPRESSIVE <br /> LOCATION OF CONCRETE PLACEMENT (days) (lbs) force) STRENGTH(psi) PASS Y/N ' <br /> 8A 3/29/02 Garage Floor 4/5 7 28.5 112700 3990 C <br /> 8B 4/1/02 West Side 4/26 28 <br /> 8C 4/26 28 <br /> 8D <br /> sp <br /> • <br /> Date Report Prepared: <br /> ASTM C 31 Standard Practice for Making and Curing Concrete Test Specimens in the Field April 5, 2002 <br /> ASTM C 39 Standard Test Method for Compressive Strength of Cylindrical Concrete Test Specimens <br /> ASTM C 94 Standard Specification for Ready-Mix Concrete <br /> ASTM C 138 Standard Test Method for Unit Weight,Yield&Air Content(Gravimetric)of Concrete <br /> ASTM C 143 Standard Test Method for Slump of Hydraulic Cement Concrete <br /> ASTM C 172 Standard Practice for Sampling Freshly Mixed Concrete <br /> ASTM C 173 Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method <br /> ASTM C 231 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method <br /> ASTM C 1064 Standard Test Method for Temperature of Freshly Mixed Portland Cement Concrete <br /> Test specimens were cast by GME Consultants, Inc. <br /> ▪ Test specimens were not cast by GME Consultants-No other information is available <br /> ▪ Test specimens were cast in 6"x 12"molds net cross-sectional area of 28.27 in2 unless otherwise noted. <br /> Copies To: <br /> Types of Fracture ASTM C39 <br /> • Mr. Mike Benedict-Frana&Sons , <br /> • Mr. Dan Saiko-Frana&Sons ` <br /> • City of Orono <br /> Ryan F.Schmidt, P.E. <br /> Cone Cone and Split Cone and Shear Shear Cewmner Project Engineer <br /> (a) (b) (o) (d) (e) <br />