Laserfiche WebLink
CONCRETE STRENGTH REPORT <br /> anfriGME Consultants, Inc. <br /> Project and Location: Orono Woods Senior Apartments. Orono, Minnesota 14000 21st Avenue North <br /> Architect/Engineer: Miller Hanson Westerbeck Berger. Inc. Minneapolis, MN 55447 <br /> General Contractor: Frana & Sons I � Ph. (763)559-1859 <br /> Concrete Contractor: Hicks Concrete It.+inr,/ Fax(763)559-0720 <br /> Owner/Developer: Wedum Foundation <br /> GME Project Number: 9212-A <br /> CONCRETE SUPPLIER. Aggregate Industries ] PLANT: MIX: -1 CUMULATIVE QUANTITY: YDS <br /> SPECIFIED <br /> MIX WAS NOT PLASTICIZED: SLUMP(inch): SPECIFIED AIR CONTENT(%): 4000 <br /> REQUIRED STRENGTH AT 28 DAYS: psi <br /> DATE CAST SLUMP(inch) TEMPERATURE <br /> DATE BEFORE AFTER DATE AGE CYL WT. MAX LOAD(Ibs- <br /> SET NUMBER RECEIVED PLASTICIZER PLASTICIZER AIR% MIX PF) AIR Q F) TIME TRUCK# TESTED (days) COMPRESSIVE <br /> LOCATION OF CONCRETE PLACEMENT _ (lbs) force) STRENGTH(psi)'PASS Y/N * <br /> 10A 4/8/02 Slab on Grade 4/15 7 27.8 96500 3410 C <br /> 10B 4/9/02 Garage-NE corner 5/6 28 <br /> 10C 5/6 28 <br /> 10D <br /> sp <br /> Date Report Prepared: <br /> ASTM C 31 Standard Practice for Making and Curing Concrete Test Specimens in the Field April 15, 2002 <br /> ASTM C 39 Standard Test Method for Compressive Strength of Cylindrical Concrete Test Specimens <br /> ASTM C 94 Standard Specification for Ready-Mix Concrete <br /> ASTM C 138 Standard Test Method for Unit Weight,Yield&Air Content(Gravimetric)of Concrete <br /> ASTM C 143 Standard Test Method for Slump of Hydraulic Cement Concrete <br /> ASTM C 172 Standard Practice for Sampling Freshly Mixed Concrete <br /> ASTM C 173 Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method <br /> ASTM C 231 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method <br /> ASTM C 1064 Standard Test Method for Temperature of Freshly Mixed Portland Cement Concrete <br /> Test specimens were cast by GME Consultants, Inc. <br /> Test specimens were not cast by GME Consultants-No other information is available <br /> -. Test specimens were cast in 6"x 12"molds net cross-sectional area of 28.27 in2 unless otherwise noted. <br /> Copies To: <br /> Types of Fracture ASTM C39 <br /> • Mr. Mike Benedict-Frana&Sons <br /> • Mr. Dan Saiko-Frana&Sons <br /> • City of Orono — UR, <br /> Ryan F. Sch_m dt,�t <br /> Cone cone end Split Cone and Sheer Sheer columnar Project Engineer <br /> (a) (b) Ie) (d) (e) <br />