CONCRETE STRENGTH REPORT - GME Consultants, Inc. <br /> Project and Location: Orono Woods Senior Apartments. Orono. Minnesota Emil 14000 21st Avenue North <br /> Architect/Engineer: Miller Hanson Westerbeck Berger, Inc. ' Minneapolis,MN 55447 <br /> General Contractor: Frana & Sons ,�`3 Ph. (763)559-1859 <br /> Concrete Contractor: Hicks Concrete ``J Fax(763)559-0720 <br /> Owner/Developer: Wedum Foundation <br /> GME Project Number: 9212-A <br /> CONCRETE SUPPLIER: Aggregate Industries PLANT: MIX: CUMULATIVE QUANTITY: YDS <br /> SPECIFIED <br /> MIX WAS NOT PLASTICIZED: SLUMP(inch): SPECIFIED AIR CONTENT)%): REQUIRED STRENGTH AT 28 DAYS: 4000 psi <br /> DATE CAST SLUMP(inch) TEMPERATURE <br /> DATE BEFORE AFTER DATE AGE CYL WT. MAX LOAD(lbs- COMPRESSIVE <br /> SET NUMBER RECEIVED LOCATION OF CONCRETE PLACEMENT PLASTICIZER PLASTICIZER AIR% MIX 1°F) AIR f F) TIME TRUCK# TESTED (days) (lbs) force) STRENGTH(psi) PASS Y/N ' <br /> 10A 4/8/2002 Slab on Grade 4/15 7 27.8 96500 3410 C <br /> 10B 4/9/2002 Garage-NE corner 5/6 28 27.9 115200 4070 Y D <br /> 10C 5/6 28 27.8 124600 4410 Y C <br /> 10D sp <br /> Date Report Prepared: <br /> ASTM C 31 Standard Practice for Making and Curing Concrete Test Specimens in the Field April 15, 2002 <br /> ASTM C 39 Standard Test Method for Compressive Strength of Cylindrical Concrete Test Specimens <br /> ASTM C 94 Standard Specification for Ready-Mix Concrete <br /> ASTM C 138 Standard Test Method for Unit Weight,Yield&Air Content(Gravimetric)of Concrete May 6, 2002 <br /> ASTM C 143 Standard Test Method for Slump of Hydraulic Cement Concrete <br /> ASTM C 172 Standard Practice for Sampling Freshly Mixed Concrete <br /> ASTM C 173 Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method <br /> ASTM C 231 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method <br /> ASTM C 1064 Standard Test Method for Temperature of Freshly Mixed Portland Cement Concrete <br /> Test specimens were cast by GME Consultants, Inc. <br /> -+ Test specimens were not cast by GME Consultants-No other information is available <br /> -. Test specimens were cast in 6"x 12"molds net cross-sectional area of 28.27 in2 unless otherwise noted. <br /> Copies To: Types of Fracture ASTM C39 <br /> • Mr.Mike Benedict-Frana&Sons _ <br /> • Mr. Dan Saiko Frana&Sons <br /> - <br /> • City of Orono <br /> Ryan F. Sch idt, P.E. <br /> co e clo e a d SP...co e sbea, sea, cowmne, Project Engineer <br /> ,al lb) Ic, ,di ,e1 <br />