Laserfiche WebLink
CONCRETE STRENGTH REPORT ,)D (zz <br /> (-) (,Oa GME Consultants, Inc. <br /> Project and Location: Orono Woods Senior Apartments. Orono, Minnesota cm 14000 21st Avenue North <br /> Architect/Engineer: Miller Hanson Westerbeck Berger. Inc. Minneapolis, MN 55447 <br /> Ei '. . <br /> General Contractor: Frana & Sons ..,,�.r Ph. (763)559 1859 <br /> Concrete Contractor: Hicks Concrete Fax Fax(763)559-0720 <br /> Owner/Developer: Wedum Foundation <br /> GME Project Number: 9212-A <br /> CONCRETE SUPPLIER: <br /> Aggregate Industries 1 PLANT: MIX: CUMULATIVE QUANTITY: YDS <br /> SPECIFIED <br /> SLUMP(inch): N/A SPECIFIED AIR CONTENT(%): 3000 REQUIRED STRENGTH AT 28 DAYS: 3000 psi <br /> MIX WAS NOT PLASTICIZED <br /> DATE CAST SLUMP(inch) TEMPERATURE <br /> DATE BEFORE AFTER DATE AGE CYL WT. MAX LOAD(lbs- COMPRESSIVE <br /> SET NUMBER RECEIVED PLASTICIZER PLASTICIZER AIR% MIX P F) AIR P F) TIME TRUCK# TESTED (days) (lbs) force) STRENGTH(psi) <br /> VEPASS YIN <br /> LOCATION OF CONCRETE PLACEMENT <br /> 4A 1/22/02 North Wall-Middle Section 1/29 7 29.7 115300 4080 C <br /> 4B 1/23/02 2/19 28 29.8 155000 5480 Y C <br /> 4C <br /> 2/19 28 29.9 168100 5950 Y C <br /> _ <br /> 4Dsp <br /> Date Report Prepared: <br /> ASTM C 31 Standard Practice for Making and Curing Concrete Test Specimens in the Field January 29, 2002 <br /> ASTM C 39 Standard Test Method for Compressive Strength of Cylindrical Concrete Test Specimens <br /> ASTM C 94 Standard Specification for Ready-Mix Concrete <br /> ASTM C 138 Standard Test Method for Unit Weight,Yield&Air Content(Gravimetric)of Concrete February 19, 2002 <br /> ASTM C 143 Standard Test Method for Slump of Hydraulic Cement Concrete <br /> ASTM C 172 Standard Practice for Sampling Freshly Mixed Concrete <br /> ASTM C 173 Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method <br /> ASTM C 231 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method <br /> ASTM C 1064 Standard Test Method for Temperature of Freshly Mixed Portland Cement Concrete <br /> Test specimens were cast by GME Consultants, Inc. <br /> -4 Test specimens were not cast by GME Consultants-No other information is available <br /> .. Test specimens were cast in 6"x 12"molds net cross-sectional area of 28.27 in2 unless otherwise noted. <br /> Copies To: Types of Fracture ASTM C39 <br /> • Mr. Mike Benedict-Frana&Sons IP <br /> • Mr. Dan Saiko-Frana&Sons <br /> 1 \ <br /> • City of OronoI - Waft-- ` <br /> Ryan F.Schmidt, •.E. <br /> ' Project Engineer <br /> �.:, (i-ii rn h0 (") <br />