Laserfiche WebLink
16403.0CBS .PERMIT SET <br /> 3-8-2017 <br /> CERTIFICATION CLIENT APPROVAL SHEET INDEX <br /> I HEREBY CERTIFY THAT THIS PLAN, AS A REPRESENTATIVE OF: <br /> SPECIFICATION OR REPORT WAS PREPARED BY <br /> ME OR UNDER MY DIRECT SUPERVISION,AND IACCEPT AND APPROVE THE INFORMATION PRESENTED <br /> THAT I AM A DULY LICENSED ARCHITECT UNDER IN THIS DRAWING SET AS A REPRESENTATION OF OUR <br /> THE LAWS OF THE STATE OF MINNESOTA. DESIGN INTENT. SHOULD OWNER INITIATE CHANGES <br /> THAT RESULT IN REVISIONS AND/OR MODIFICATIONS <br /> ADDITIONAL DESIGN SERVICE FEES WILL BE CHARGED. <br /> SHEET# SHEET DESCRIPTION <br /> TO; • • AGEN,AIA, NCARB <br /> ARCHITECTURAL <br /> REGISTR •N NUMBER: 18074 TITLE: <br /> A000 TITLE SHEET, CODE REVIEW,AREA MAP 0 <br /> A200 LOWER AND FIRST LEVEL FLOOR PLANS 0 <br /> A201 SEOND LEVEL FLOOR PLAN 0 <br /> APPLICABLE CODES A400 ENLARGED TOILET PLANS AND ELEVATIONS 0 <br /> INTERNATIONAL BUILDING CODE (IBC) 2012 <br /> AMENDMENTS IN MSBC: CHAPTER 1300 2015 <br /> AMENDMENTS IN MSBC: CHAPTER 1341 2015 <br /> AMENDMENTS IN MSBC: CHAPTER 1307 2015 <br /> INTERNATIONAL FIRE CODE (IFC) 2012 <br /> INTERNATIONAL MECHANICAL AND FUEL GAS CODE 2012 <br /> AMENDMENTS IN MSBC: CHAPTER 1346 2015 <br /> STATE BUILDING CODE (MSBC) 2015 <br /> MN PLUMBING CODE 2015 <br /> INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2012 W/ASH RAE 90.1-2010 CRITERIA <br /> AMENDMENTS IN MSBC: CHAPTER 1323 2015 <br /> NATIONAL ELECTRICAL CODE 2014 <br /> MN STATE FIRE CODE 2015 <br /> OCCUPANCY REQUIREMENTS <br /> FIRE SPRINKLLR 1'KOl LCI ION: FULL SPRINKLED <br /> TYPE OF CONSTRUCTION: V-B <br /> BUILDING OCCUPANCY: E (DAYCARE) <br /> LOWER LEVEL USF: 3,034 SF <br /> FIRST LEVEL USF 2,960 SF <br /> SECOND LEVLE USF: 1,550 SF <br /> 1. ON THE FLOOR PLANS EACH ROOM IS NOTED WITH THE NUMBER OF STUDENTS AND _ <br /> ROOM SQUARE FOOTAGE. WITH OCCUPANCY FACTOR OF 35;TWO EXITS ARE NOT <br /> REQUIRED OUT OF THE INDIVIDUAL CLASS ROOMS. <br /> i <br /> 2. IBC 1015.6 DAY CARE MEANS OF EXIT. <br /> ROOMS WITH MORE THAN 10 STUDENTS 2.5 YEARS OF AGE OR LESS REQUIRE TWO <br /> EXITS OR EXIT ACCESS DOORWAYS. <br /> CLASSROOM#113, 105 AND 011 WILL REQUIRE TWO EXITS <br /> 3. FIRST FLOOR HAS AN ACCESSIBLE PATH TO THE ENTRANCE TO THE BUILDING <br /> 4. LOWER LEVEL HAS AN ACCESSIBLE PATH TO THE ENTRANCE TO THE BUILDING <br /> 5. SECOND LEVEL IS AN "E" OCCUPANCY: 1,550 SF -OCCUPANCY FACTOR= 100; <br /> 1550/100= 16 OCCUPANCY LESS THAN 30 THEREFORE AN ELEVATOR IS NOT <br /> REQUIRED. <br /> 6. ADULT ACCESSIBLE RESTROOMS ARE LOCATED ON LOWER LEVEL AND SECOND LEVEL. <br /> 7. CHILDREN ACCESSIBLE RESTROOMS ARE LOCATED ON FIRST FLOOR. <br /> 8. PER MN DAYCARE REGULATIONS 1 WATER CLOSET AND 1 LAVATORY IS REQUIRED PER AREA MAP <br /> EVERY 15 STUDENTS. <br /> PROPOSED: 98 STUDENTS <br /> REQUIRED: 7 WATER CLOSETS AND 7 LAVATORIES <br /> PROVIDED: 8 WATER CLOSETS AND 13 LAVATORIES <br /> ! DiCkey Luka:Or <br /> I t3ag �'L44k (A. <br /> )t*en Oats,Garden 03 <br /> iter&Landscaping <br /> SERVICE 8000 <br /> V4J,.riati.Ova0 E. 0 <br /> a ,11 <br /> vti a <br />