2016-01232 - addn/remodel/repair
Orono
>
Property Files
>
Street Address
>
W
>
Wayzata Boulevard West
>
2060 Wayzata Boulevard West - (Common Area & Units)
>
2060 Wayzata Blvd W - 34-118-23-21-0037 - (Unit 100/150)
>
Permits/Inspections
>
2016-01232 - addn/remodel/repair
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:55:53 PM
Creation date
1/7/2020 11:52:50 AM
Metadata
Fields
Template:
x Address Old
House Number
2060
Street Name
Wayzata
Street Type
Boulevard
Street Direction
West
Address
2060 Wayzata Blvd W
Document Type
Permits/Inspections
PIN
3411823210040
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
View images
View plain text
NOTES: N.R.—Not required <br /> N.A.—Not applicable <br /> ADMINISTRATION (Chapter 1) <br /> Complete construction documents Signed/sealed construction documents <br /> (107.1, 107.2) (107.1, State laws vary) <br /> BUILDING PLANNING (Chapters 3, 4, 5, 6) <br /> OCCUPANCY CLASSIFICATION(302-312,508,509) <br /> XSingle Occupancy (302.1) Incidental uses (509, Table 509) <br /> Mixed Occupancy(508.1) Accessory occupancies (508.2) <br /> GENERAL BUILDING LIMITATIONS(Chapters 5&6) <br /> Address identification (501.2) <br /> Apply Case 1 to determine the allowable height and area and permitted types of construction for building containing a <br /> single occupancy or nonseparated mixed occupancies. Apply Case 2 to determine the allowable height and area and <br /> permitted types of construction for a building containing separated mixed occupancies. <br /> AREA MODIFICATIONS TO TABLE 503 <br /> Allowable tabular area,At(Table 503) 1 Frontage <br /> (506.2) <br /> Area Increase Factor due to frontage, North East South West <br /> If(506.2) + Total <br /> Frontage (F) __ 't. Perimeter(P) ft. <br /> Area Increase Factor due to automatic Width of open space(W)= <br /> sprinklers, I,(506.3) + _ <br /> Area Increase Factor <br /> due to frontage, 1,= <br /> Conversion factor .......__ (506.2) <br /> It= [P-0.25]o <br /> LV <br /> CASE 1 —SINGLE OCCUPANCY OR NONSEPARATED MIXED OCCUPANCIES(508.3) <br /> Using Table 503, identify the allowable height and area of the single occupancy or the most restrictive of the nonsepa- <br /> rated mixed occupancies.Construction types that provide an allowable tabular area equal to or greater than the adjusted <br /> building area and allowable heights(as modified by Section 504) equal to or greater than the actual building height are <br /> permitted. <br /> DETERMINE CONSTRUCTION TYPE CHECK ALLOWABLE AREA(506.4) <br /> Actual building area ft2 Allowable area per floor(A,) <br /> Adjusted building area ft2 X = ft2 <br /> actual building area+conversion factor conversion factor tabular area(Table 503) <br /> Actual building height feet stories Total floor area(all stories) ft2 <br /> Allowable building height feet stories Allowable floor area(all stories) <br /> Permitted types of construction x = ft2 <br /> Allowable area per floor number of stories <br /> Type of construction assumed (AJ (maximum 3) <br /> for review(602.1) Compliance verified <br /> -4- <br />
The URL can be used to link to this page
Your browser does not support the video tag.
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).