N
<br />to
<br />ATRIUMcl�r.
<br />am b,
<br />il'��-:'
<br />A 5 0,M
<br />F- RUN 3/4" HW, CW & RECIRC. HW 1 ` RUN 3/4" HW, CW & RECIRC. HIN
<br />UP TO FLOORS ABOVE - REFER TO UP TO FLOORS ABOVE - REFER TO
<br />2
<br />I 2/M1. /1M1.
<br />Ie i' 1-1/2" WASTE DN. 1-1 j2" WASTE DN.
<br />1 FROM ABOVE r' - FROM ABOVE
<br />I� ' OPTIONAL CLEAN-OUT IN
<br />CLEAN-OUT IN t "`-�-_�_ � .
<br />1 JOISTS SPACE - f' ELEVATOR JOISTS SPACE 1 "
<br />3" VENT r BY OTHERS TEI , , 3 VENT
<br />< < -' I I ��
<br />STACK UP - STACK UP
<br />OJ r4" WASTE DN. WATER HTR 1�� 4" WASTE DN.�_
<br />• OPTIONAL FROM ABOVE
<br />Q FROM ABOVE NM_1 ,� ELEV. E.
<br />L i�x r BY OTHERS 3/4" CW
<br />3/4- CW , ME... H4`11L 1 " t
<br />UP TO 3" WASTE ROUGH -IN 3 WASTE ROUGH-INUP TO
<br />FLOOR ABV. , FOR FUTURE WATER E `SIJ FOR FUTURE WATER '
<br />CLOSET ON FLR. ABV FLOOR __, CLOSET ON FLR. ABV.
<br />t FLOOR ABV.
<br />C.O.
<br />F-3 METER METER M i
<br />I
<br />E=1 FLOOR'_,
<br />RUN PIPING= C 0 RUN PIPING
<br />IN JOIST r_• _ IN JOIST
<br />FREEZE -PROOF ' t SPACE `' "� j i i` ' SPACE
<br />LOCKABLE WALL '` t (j
<br />� � ^ � ..,-"."�!<..,.� � Yom/ T �� •
<br />HYDRANTNe�. ` s uuu
<br />,.�^ y � • '+"ter • `�.. ����I/_s � zr t - �
<br />i i �•" �v P
<br />C
<br />M
<br />BUILDING
<br />NN
<br />14
<br />CLEAN-OUT " 1-1/2" WASTE DN.
<br />�- n' x- 1-1/2 WATER
<br />`� & 1-1/2"
<br />CLEAN-OUT iN " WASTE TO SERVICE TO CLEAN-OUT IN—
<br />JOISTS
<br />N VENT UP -
<br />4
<br />JOISTS SPACE 5-0" FROM BUILDING BY JOISTS SPACE a WASTE STACK DN.
<br />BUILDING OTHERS
<br />LEVEL 3/4" CW UP FROM BELOW.
<br />1 PLUMBING PLAN — LOWEST
<br />VALVE
<br />CLOSET. EXTEND/
<br />TEND
<br />1 2" CW UP TO FLOOR
<br />M1 SCALE: 1/8"=l' -O" eovE
<br />3" VENT UP
<br />U
<br />C
<br />N
<br />.0
<br />v
<br />a.
<br />E
<br />0
<br />U
<br />0
<br />v
<br />n
<br />r -
<br />N
<br />OJ
<br />WASTE & VENT
<br />SUPPLY
<br />1 PLUMBING RISER DIAGRA
<br />M, J NO SCALE
<br />ELECTRIC WATER
<br />HEATER
<br />WATER
<br />HEATER
<br />NO.
<br />LOCATION
<br />SERVICE
<br />STORAGE
<br />CAPACITY
<br />GALLONS
<br />ELECTRICAL
<br />REMARKS
<br />WH -1
<br />BASEMENT
<br />SINKS
<br />20
<br />115/60/1
<br />J
<br />1
<br />1
<br />1
<br />1
<br />1
<br />1
<br />PROVIDE 3/4" HW, CW &
<br />RECIRCULATING HW UP FROM
<br />BELOW W/ 1/2' VALVED &
<br />CAPPED TAKE -OFFS FOR
<br />FUTURE LAVATORY THIS FLOOR.
<br />EXTEND 1/2" HW & CW UP TO
<br />FLOOR ABOVE
<br />® 11
<br />v
<br />TOILET RNI
<br />-� RO'.;GI-+-N,
<br />LOFT --LINE
<br />>� ABOVE
<br />3" WASTE ROUGH -IN
<br />FOR FUTURE WATER
<br />CLOSET ON FLOOR
<br />ABOVE
<br />EXPANSION
<br />TANK
<br />TTENANT
<br />�i
<br />ATRIUM
<br />I I
<br />} OPi1CNAL
<br />if ELEVATOR
<br />�t BY O -HERS
<br />N
<br />2 PLUMBING
<br />M1 J SCALE: 1/8'=1'-0'
<br />FUTURE RECIRCULATING
<br />HW PUMP
<br />PLUMBING FIXTURE
<br />PIPING
<br />FIXTURE
<br />PiPE SIZE (INCHES)
<br />REMARKS
<br />NO.
<br />TYPE
<br />W. V.
<br />C. W.
<br />H. W.
<br />F-1
<br />WATER CLOSET
<br />4 2
<br />1/2
<br />-
<br />Waste and vent piping in building above and below ground to be schedule 40 PVC DWV pipe and drainage
<br />F-2
<br />LAVATORY
<br />1-1/2 1-1/2
<br />1/2
<br />1/2
<br />using 95-5 Bridgit solder. Short connections to fixtures and equipment may be Type L soft drawn copper.
<br />IF -3
<br />JANITORS SINK
<br />13 12
<br />3/4
<br />3/4
<br />Furnish and install valves required to isolate fixtures, equipment and segments of the piping systems. Valves
<br />PROVIDE 3/4 HW, CW &
<br />RECIRCULATING HW UP FROM
<br />BELOW W/ 1/2" VALVED &
<br />CAPPED TAKE -OFFS FOR
<br />FUTURE LAVATORY THIS FLOOR.
<br />EXTEND 1/2" HW & CW UP TO
<br />FLOOR ABOVE
<br />TOILE1i RM
<br />ROS I� I 'N
<br />3" WASTE ROUGH -IN
<br />FOR FUTURE WATER
<br />CLOSET ON FLOOR
<br />ABOVE
<br />TE'NA
<br />1-1/2" WASTE DN.
<br />& 1-1/2" VENT UP -
<br />3" VENT STACK:
<br />1/2" CW UP'FROM
<br />BELOW. VALV &
<br />CAP FOR FUURE
<br />WATER CLOST 4" WASTE DN.-
<br />& 4" VENT UP
<br />MECHANICAL SPECIRCATIOVS
<br />GENERAL
<br />The Mechanical Work includes work as indicated on the drawings to provide complete plumbing systems installations.
<br />Provide all construction engineering, supervision, labor, material and any and all items necessary for complete
<br />and functioning installations.
<br />Comply with all Owner requirements.
<br />Obtain all permits required for the Mechanical Work and arrange for inspections as required by the city
<br />Inspection Department.
<br />Pay all sales taxes, fees, permit and other costs pertaining to the Mechanical Work.
<br />Coordinate the Mechanical Work with the General Contractor and other sub -contractors.
<br />All work is to be performed in a craftsmanship manner, and except where otherwise indicated, using only new,
<br />quality materials.
<br />TENANT
<br />--
<br />__
<br />PROVIDE 1/2" HW & CW
<br />UP FROM BELOW. VALVE
<br />& CAP FOR FUTURE
<br />LAVATORY
<br />TOILET Rel
<br />ROUGH -IN 01
<br />\N---LOFT--LINE
<br />4" V.T.R. ABOVE
<br />Provide 20 year white silicone caulk between the back edges of vitreous china fixtures and adjoining wall surfaces.
<br />ATRIUM
<br />i�
<br />I OPEN TO 6
<br />NAL K'
<br />i
<br />r� OPTIONAL
<br />1
<br />ELEVATOR
<br />r` BY OTHERS
<br />31 PLUMBING PLAN —
<br />M1 J SCALE: 1/8R=1 -0"
<br />PROVIDE 1/2" HW & CW
<br />UP FROM BELOW. VALVE
<br />& CAP FOR FUTURE
<br />LAVATORY
<br />r
<br />TOILET RptROUGH -iN
<br />{ ��
<br />r`
<br />t V-�
<br />e V.T.R.
<br />!r 1-1/2 -
<br />-1/2" WASTE DN.
<br />,--& 1-1/2 VENT UP
<br />---3" VENT STACK
<br />1/2' CW UP FROM
<br />BELOW. VALVE &
<br />CAP FOR FUTURE
<br />4" WASTE DN. WATER CLOSET
<br />& 4" VENT UP
<br />Palo
<br />Drafting / Design
<br />Residential & Commercial
<br />Design & Construction Plans
<br />14208 US Hwyy 12 E.
<br />Cok%, Mn.
<br />55321
<br />Business:
<br />Do all cutting and patching necessary for the installation of the Mechanical Work. All cutting shall be done in a
<br />286-6133
<br />manner directed by the General Contractor. Patching shall match adjacent surfaces.
<br />877
<br />All electrical power wiring will be furnished and installed by the Electrical Contractor.
<br />Fax:(20)
<br />Make an operating test of the completed installations and remedy all defects disclosed as a result of the test.
<br />286-3230
<br />Guarantee all workmanship and material against defects for at least one year from the date of Owners
<br />acceptance.
<br />PLUMBING
<br />Waste and vent piping in building above and below ground to be schedule 40 PVC DWV pipe and drainage
<br />fittings.
<br />Water piping above grade to be Type L hard drawn copper tubing and wrought copper solder fittings joined
<br />using 95-5 Bridgit solder. Short connections to fixtures and equipment may be Type L soft drawn copper.
<br />Underground water service piping shall be Type K, soft drawn seamless copper tubing. Underground branch
<br />piping shall be Type K. soft drawn or PEX. Joints will not be permitted in buried piping.
<br />Furnish and install valves required to isolate fixtures, equipment and segments of the piping systems. Valves
<br />shall be ball type.
<br />Support piping from structure with adjustable hangers.
<br />Furnish and install floor drains where indicated on the Drawings. Floor drains shall be Josam 30003 -AJ, cast
<br />iron body, bottom outlet, backwater valve, nickel bronze round adjustable strainer.
<br />Furnish and install cleanouts. Floor cleanouts shall be constructed with frame and cover threaded for 2" vertical
<br />adjustment, cast iron round frame and cover.
<br />Pitch horizontal waste piping 1/4" per foot where possible, but in no cost less than 1/8" per foot.
<br />Through -the -roof extensions of soil and waste stacks shall terminate 12 inches above the roof.
<br />% 1-1/2' WASTE DN.
<br />f & 1-1/2" VENT UP
<br />F-1 Water Closet: American Standard "Cadet 3", 16-1/2" high floor set vitreous china, 12" rough -in, siphon jet,
<br />/=
<br />1.6 GPF elongated flush tank. Seat: Olsonite 95 -CC -SS, or approved equal, white solid plastic seat, open front,
<br />4 " WASTE STACK DN.
<br />check hinge, for elongated bowl. Closet waste fitting with neoprene gasket.
<br />_
<br />F-2 Lavatory. American Standard "Luceme", 19 5/8" x 16 3/4" x 6" deep vitreous china, self rimming sink
<br />with overflow. Chicago model 802-V336CP deck mounted, vandal resistant self-closing faucet with 0.5 GPM
<br />_v 3/4" CW UP FROM BELOW.
<br />flow, P trap and supplies and loose key handle angle stops.
<br />VALVE & CAP FOR FUTURE
<br />WATER CLOSET. EXTEND
<br />Disinfect the complete water piping system in accordance with Minnesota Health Department recommended
<br />1/2" CW UP TO FLOOR
<br />procedures.
<br />ABOVE
<br />Treat the system with chlorine and flush with clean water. Open and close all affected valves during the
<br />disinfecting period. Repeat as necessary to pass required bacteriological tests.
<br />3" VENT UP
<br />Insulate all above ground water piping with Armstrong AP Armoflex foamed tubing insulation, 3/4" thick.
<br />FIXTURE INSTALLATIONS
<br />Fixtures shall be owner furnished, set in place and properly connected, complete in every detail,
<br />to soil, waste, vent and water pipes. Fixtures shall be rigid, set plumb, level and true.
<br />Furnish and install all brackets,- plates, brads and/ -.r reinforcing angles as required to support wall
<br />hung plumbing fixtures. Supporting members shall be rigidly attached to the walls and wall structures.
<br />Particular care shall be exercised in hanging fixtures, especially lavatories, to assure rigidity and
<br />permanence.— This 'ohtractor will be`held responsible ora secure moun Ifng` onava odes on the
<br />hangers and any breakage resulting from improper installation of any fixture.
<br />Correctly faced inlets for fixtures shall be provided. Branches of soil, waste and vent pipe shall be
<br />extended as close to fixtures as possible. Branches of vent pipes shall be graded to the trop.
<br />Fixture wastes, other than water closets and trap standard fixtures, shall be connected to waste
<br />lines with an iron ferrule and threaded pipe.
<br />Mounting heights as required by local building code w/ jurisdiction.
<br />TENANT
<br />--
<br />__
<br />PROVIDE 1/2" HW & CW
<br />UP FROM BELOW. VALVE
<br />& CAP FOR FUTURE
<br />LAVATORY
<br />TOILET Rel
<br />ROUGH -IN 01
<br />\N---LOFT--LINE
<br />4" V.T.R. ABOVE
<br />Provide 20 year white silicone caulk between the back edges of vitreous china fixtures and adjoining wall surfaces.
<br />ATRIUM
<br />i�
<br />I OPEN TO 6
<br />NAL K'
<br />i
<br />r� OPTIONAL
<br />1
<br />ELEVATOR
<br />r` BY OTHERS
<br />31 PLUMBING PLAN —
<br />M1 J SCALE: 1/8R=1 -0"
<br />PROVIDE 1/2" HW & CW
<br />UP FROM BELOW. VALVE
<br />& CAP FOR FUTURE
<br />LAVATORY
<br />r
<br />TOILET RptROUGH -iN
<br />{ ��
<br />r`
<br />t V-�
<br />e V.T.R.
<br />!r 1-1/2 -
<br />-1/2" WASTE DN.
<br />,--& 1-1/2 VENT UP
<br />---3" VENT STACK
<br />1/2' CW UP FROM
<br />BELOW. VALVE &
<br />CAP FOR FUTURE
<br />4" WASTE DN. WATER CLOSET
<br />& 4" VENT UP
<br />Palo
<br />Drafting / Design
<br />Residential & Commercial
<br />Design & Construction Plans
<br />14208 US Hwyy 12 E.
<br />Cok%, Mn.
<br />55321
<br />Business:
<br />320)
<br />286-6133
<br />Toll Free:
<br />877
<br />517-6133
<br />Fax:(20)
<br />R20)
<br />286-3230
<br />After Hours:
<br />275-3082
<br />Email: Iehto_tim@yahoo.com
<br />DISCLAIMER:
<br />PALO COMPANIES ASSUMES NO RESPONSIBILITIES
<br />FOR THE DRAWINGS ON THIS SHEET. A CLIENT
<br />WHO PURCHASES THiS DOCUMENT IS RESPONSIBLE
<br />FOR MEETING ALL LOCAL, STATE & FEDERAL LAWS
<br />ASSOCIATED WITH TYPE OF WORK REPRESENTED
<br />ON THIS SHEET. EMPLOYEES OF PALO COMPANIES
<br />ARE Q ARCHITECTS OR ENGINEERS AND ASSUME
<br />NO SUCH RESPONSIBILITIES.
<br />IF A CLIENT WiSHES,
<br />PALO COMPANIES CAN CONTACT ARCHITECTS &
<br />ENGINEERS WHO WILL REVIEW AND CERTIFY
<br />DOCUMENTS 121AT DO COMPLY WITH ALL LOCAL,
<br />STATE & FEDERAL BUILDING CODES & LAWS. THE
<br />FEES FOR SUCH DOCUMENTS ARE NOT INCLUDED
<br />IN PALO COMPANIES BIDS OR ESTIMATES.
<br />I hereby certify that this plan,
<br />specification or report was pre—
<br />pared by me or under my direct
<br />supervision and that I am a duty
<br />Licensed Master Plumber
<br />under the lows of the State of
<br />Minnesota.
<br />Edward S. Lehto
<br />Date: 12/14/07 Reg. No.: 5693PM
<br />M
<br />W
<br />o
<br />10
<br />L
<br />00
<br />■ s
<br />p -0
<br />E
<br />> O
<br />>� m 00
<br />.0."
<br />Cc CC i
<br />O ICU
<br />cc
<br />O ca CL
<br />c
<br />LM
<br />■O
<br />. ■�
<br />E
<br />E�
<br />'cC cit Z 0=
<br />PROJECT 07-017
<br />P//86.3
<br />DRAWN TEL
<br />DATE 12/14/07
<br />REVISIONS
<br />SHEET 1 OF 1
<br />
|