My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Geotechnical Evaluation Report
Orono
>
Property Files
>
Street Address
>
W
>
Wayzata Boulevard West
>
0875 Wayzata Boulevard West - 35-118-23-44-0011
>
Misc
>
Geotechnical Evaluation Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:59:54 PM
Creation date
1/6/2020 10:11:57 AM
Metadata
Fields
Template:
x Address Old
House Number
875
Street Name
Wayzata
Street Type
Boulevard
Street Direction
West
Address
875 Wayzata Boulevard West
Document Type
Misc
PIN
3511823440011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Kraus-Anderson Realty Company <br /> Project BL-11-01014 <br /> March 18, 2011 <br /> Page 8 <br /> Table 1.Anticipated Excavation Depths at Borings in or near Building Pad <br /> Anticipated Corresponding <br /> Soil Correction Elevation of Soil Depth Below FFE <br /> Surface Elevation Depth Correction of 968 <br /> Boring (feet MSL) (feet) (feet MSL) (feet MSL) <br /> ST-101 963.6 3 960 1/2 7 1/2 <br /> ST-103 966.6 4 962 1/2 5 1/2 <br /> ST-104 967.6 19 948 1/2 19 1/2 <br /> ST-105 966.1 19 947 21 <br /> ST-106 961.9 4 958 10 <br /> ST-107 965(estimated) 4 961(estimated) 7 <br /> ST-3* 964.5 4 960 1/2 7 1/2 <br /> ST-6* 961.5 1 960 1/2 7 1/2 <br /> ST-7* 965.1 1/2 964 1/2 3 1/2 <br /> ST-8* 967.3 1 1/2 966 2 <br /> *Boring performed during previous exploration. <br /> Note that Boring ST-104 was estimated to be about 30 to 40 feet south of the south corner of the east <br /> wing. Boring ST-104 encountered deep organic soils and we assume the poor soil conditions will <br /> encroach into the building pad and oversize areas. However, surrounding Borings ST-103 and ST-107 did <br /> not encounter the deep organic soil conditions. <br /> We also anticipate helical anchors will be installed for canopy footing support in the area of deep <br /> organics found in Boring ST-105.The above soil correction depth shown for Boring ST-105 would not be <br /> applicable if helical anchors are utilized. <br /> The actual depths of excavations needs to be determined in the field at the time of construction by a <br /> geotechnical engineer,or qualified representative. An experienced engineering technician should work <br /> closely with the excavating contractor during excavations to make the necessary field judgments <br /> regarding the suitability of the exposed soils and to determine the extent of fill and other unsuitable <br /> soils. <br /> To provide lateral support of the structural loads they will support,we recommend oversizing (widening) <br /> the excavations 1 foot horizontally beyond the footings for each foot the excavations extend below <br /> bottom-of-footing elevations. If the extent of the oversizing is verified by a surveyor prior to filling,the <br /> oversizing can be reduced to 1/2 to 1 (horizontal to vertical). <br /> BRAUN <br /> INTERTEC <br />
The URL can be used to link to this page
Your browser does not support the video tag.