My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Soil and percolation testing
Orono
>
Property Files
>
Street Address
>
W
>
Wayzata Boulevard West
>
0920 Wayzata Boulevard West - 35-118-23-41-0006
>
Septic
>
Soil and percolation testing
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:59:29 PM
Creation date
12/31/2019 12:35:22 PM
Metadata
Fields
Template:
x Address Old
House Number
920
Street Name
Wayzata
Street Type
Boulevard
Street Direction
West
Address
920 Wayzata Boulevard West
Document Type
Septic
PIN
3511823410006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Pressure Distribution <br /> UNIVERSITY <br /> Minnesota Pollution Design Worksheet OF MINNESOTA :__-__; <br /> Control Agency . <br /> 1. Select Number of Perforated Laterals in system/zone: I _3 I Geoteatile n1,',M a'V,:aeg rti m ice <br /> Minimu -'. • T <br /> i i-, <br /> (2 feet is minimum and 3 feet is maximum spacing) ;). '�+�Perforations spaced 3`apart ;u <br /> 2'of rock <br /> : Ty ;- <br /> 2. Select Perforation Spacing: 3.0 ft a;�� "' -4. _ _ <br /> 3. Select Perforation Diameter Size 1 1 inch `' r` om'` <br /> Perforation sizing:'/e'to Vi" <br /> Perforation spacing:2'to 3' <br /> 4. Length of Laterals =Media Bed Length -2 Feet. Perforation can not be closer then 1 foot from edge. <br /> 38 - 2ft = 36 ft <br /> 5. Determine the Number of Perforation Spaces. Divide the Length of Laterals (Line 4)by the Perforation Spacing (Line 2)and <br /> round down to the nearest whole number. <br /> Number of Perforation Spaces = 36 ft 3 ft = 12 Spaces <br /> 6. Number of Perforations per Lateral is equal to 1.0 plus the Number of Perforation Spaces (Line 5). <br /> Perforations Per Lateral = 12 Spaces 1 = 13 Perfs. Per Lateral <br /> Check Table I to verify the number of perforations per lateral guarantees less than a 10%discharge variation. The value is double if <br /> the a center manifold is used. <br /> 7. Total Number of Perforations equals the Number of Perforations per Lateral (Line 6)multiplied by the Number of <br /> Perforated Laterals (Line 1). <br /> 13 Perf. Per Lateral X 3 Number of Perf. Laterals = 39 Total Number of Perf. <br /> 8. Calculate the Square Feet per Perforation. Recommended value is 4-10 ft 2 per perforation. <br /> Perforation Discharge(GPM) <br /> Does not apply to At-Grades Perforation Diameter <br /> Bed Area = Bed Width (ft)X Bed Length (ft) Head(ft) ,,,° r,,, •,• <br /> 10' 0.18 0.41 0.56 0.74 <br /> 10 ft X 38 ft = 380 ft2 1.5 0.22 0.51 0.69 0.9 <br /> 2.0° 0.26 0.59 0.80 1.04 <br /> 2.50.29 0.65 0.89 1.17 <br /> Square Foot per Perforation =Bed Area divided by the Total Number of Perforations (Line 7). 3.0 0.32 0.72 0.98 1.28 <br /> 4.0 0.37 0.83 1.13 1.47 <br /> 5.0' 0.41 0.93 1.26 t.65 <br /> 380 ft2 = 39 perforations = 9.7 ft2/perforations ,root 1/4 inch and 3/16 inch perforations on <br /> dwellings <br /> 1/8 inch perforations on dwellings and for <br /> 9. Select Minimum Average Head: 1.0 ft 2 feet other establishments <br /> 1/4 inch and 3/16 inch peforatlons on MSTS <br /> 5 feet 1/8 inch perforations on MSTS <br /> 10. Select Perforation Discharge (GPM)based on Table III: 0.74 GPM per Perforation <br /> 11. Determine required Flow Rate by multiplying the Total Number of Perforations (Line 7)by the Perforation Discharge (Line 10). <br /> 39 Perforations X 0.74 GPM per Perfora_ion = 29 GPM <br /> 12. Select Type of Manifold Connection (End or Center): 2 End ❑Center <br />
The URL can be used to link to this page
Your browser does not support the video tag.