My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Proposed Structure
Orono
>
Property Files
>
Street Address
>
W
>
Wayzata Boulevard West
>
0200 Wayzata Boulevard West - 36-118-23-43-0001
>
Misc
>
Proposed Structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:05:26 PM
Creation date
12/31/2019 11:01:51 AM
Metadata
Fields
Template:
x Address Old
House Number
200
Street Name
Wayzata
Street Type
Boulevard
Street Direction
West
Address
200 Wayzata Boulevard West
Document Type
Misc
PIN
3611823430001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ICC/ANSI A117.1-2003 Chapter 4.Accessible Routes <br /> Table 405.2—Allowable Ramp Dimensions for Construction in <br /> Existing Sites, Buildings, and Facilities <br /> Slope' Maximum Rise <br /> Steeper than 1:10 but not steeper than 1:8 3 inches(75 mm) <br /> Steeper than 1:12 but not steeper than 1:10 6 inches (150 mm) <br /> 1A slope steeper than 1:8 shall not be permitted. <br /> 405.7 Landings.Ramps shall have landings at bot- 405.9 Edge Protection. Edge protection comply- <br /> torn and top of each ramp run.Landings shall corn- ing with Section 405.9.1 or 405.9.2 shall be pro- <br /> ply with Section 405.7. vided on each side of ramp runs and at each side of <br /> ramp landings. <br /> 41 . . - • • - ..din•ssha •- - - - _•- • <br /> steeper than - • a co - • , - - ': EXCEPTIONS: <br /> • . s-rp,T� /4r-iv.- n.)&- v/orn4,vd '1° 1. Ramps not required to have handrails <br /> ro ?� where curb ramp flares complying with <br /> 405.7.2 Width.Clear width of landings shall be at Section 406.3 are provided. <br /> least as wide as the widest ramp run leading to <br /> the landing. 2. Sides of ramp landings serving an adjoin- <br /> ing ramp run or stairway. <br /> 405.7.3 Length. Landings shall have a clear <br /> length of 60 inches (1525 mm) minimum. 3. Sides of ramp landings having a vertical <br /> drop-off of/z inch(13 mm)maximum within <br /> 10 inches(255 mm)horizontally of the mini- <br /> 405.7.4 Change in Direction. Ramps that mum landing area. <br /> change direction at ramp landings shall be sized <br /> to provide a turning space complying with Sec- 405.9.1 Extended Floor Surface.The floor sur- <br /> tion 304.3. face of the ramp run or ramp landing shall extend <br /> 12 inches (305 mm) minimum beyond the inside <br /> 405.7.5 Doorways. Where doorways are adja- face of a railing complying with Section 505. <br /> cent to a ramp landing, maneuvering clearances <br /> required by Sections 404.2.3 and 404.3.2 shall 405.9.2 Curb or Barrier.A curb or barrier shall <br /> be permitted to overlap the landing area.Where be provided that prevents the passage of a 4-inch <br /> doors that are subject to locking are adjacent to a (100 mm) diameter sphere where any portion of <br /> ramp landing,landings shall be sized to provide a the sphere is within 4 inches (100 mm) of the <br /> turning space complying with Section 304.3. floor. <br /> 405.8 Handrails. Ramp runs with a rise greater 405.10 Wet Conditions. Landings subject to wet <br /> than 6 inches (150 mm) shall have handrails com- conditions shall be designed to prevent the accu- <br /> plying with Section 505. mulation of water. <br /> 60 min 60 min <br /> 60 min i / 1525 <br /> 1525 1525 <br /> l' <br /> landing ramp run landing ii ramp run landing F <br /> co <br /> � <br /> at least as wide as ramp run <br /> (a) <br /> ramp <br /> run <br /> (b) <br /> Fig.405.7 <br /> Ramp Landings <br /> 23 <br />