My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-00042 - sprinkler system
Orono
>
Property Files
>
Street Address
>
W
>
Wayzata Boulevard West
>
0200 Wayzata Boulevard West - 36-118-23-43-0001
>
Permits/Inspections
>
2009-00042 - sprinkler system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:05:09 PM
Creation date
12/30/2019 2:16:11 PM
Metadata
Fields
Template:
x Address Old
House Number
200
Street Name
Wayzata
Street Type
Boulevard
Street Direction
West
Address
200 Wayzata Boulevard West
Document Type
Permits/Inspections
PIN
3611823430001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> - • General Installation Instructions • Model G3 Wrench (Fig. 4) is used for installation of <br /> Model F3QR dry sprinklers must be installed only in Pendent and Horizontal Sidewall sprinklers. <br /> standard (ANSI B 16.3 class 150 and ANSI B 16.4 class <br /> 125)pipe tees even at branch line ends. They should not • Glass bulb sprinklers have orange bulb protectors to <br /> be installed into elbows and pipe couplings located on minimize bulb damage during shipping, handling and <br /> drop nipples to the sprinklers. For these and other fittings installation. REMOVE THIS PROTECTION AT THE TIME <br /> including CPVC*, the dry sprinkler should be installed THE SPRINKLER SYSTEM IS PLACED IN SERVICE <br /> into a fitting to conform to protrusion into the fitting in ac- FOR FIRE PROTECTION. Removal of the protectors <br /> cordance with the diagrams.The"A"dimension of the dry before this time may leave the bulb vulnerable to <br /> sprinkler, which extends into the freezers or a freezing damage. MASCO wrenches are designed to install <br /> zone from wet pipe systems, should be selected to pro- i sprinklers when covers are in place. REMOVE <br /> vide. as a.,minimum, the specified lengths in inches PROTECTORS BY UNDOING THE CLASP BY HAND. <br /> shown in the following chart, between face of the fitting DO NOT USE TOOLS TO REMOVE THE <br /> and the outside wall or ceiling of the protected area. The PROTECTORS. <br /> following chart is used for freezing zones.when the ambi • <br /> - <br /> ent temperature around the wet pipe system is kept at 40 Maintenance <br /> °F/4°C).and specifies the minimum length for fitting face The Model F3QR Quick Response Dry Sprinklers should <br /> to ceiling or wall (outside) for different protected area be inspected quarterly and the sprinkler system <br /> temperatures. maintained in accordance with NFPA 25. Do not remove <br /> I Length(Face to Ceiling/Wall) Temperature(Protected Area)* the factory applied thermally sensitive wax fillet between <br /> the bulb supporting cup and the wrenching boss. Do not <br /> 12 inches/300 mm -20°F/-29°C replace this wax with a substitute substance. An Alternate <br /> 1 18 inches/450 mm -40°F/-40°C substance may interfere with proper operation of the <br /> 24 inches/600 mm ' -60°F/-51°C°C sprinkler. Do not clean sprinklers with soap and water, <br /> "For temperatures falling between those in the above chart,the ammonia or any other cleaning fluids. Remove dust by . <br /> minimum t lengtheratmay be determined interpolation. using a soft:brush or gently vacuuming. Remove any <br /> sprinkler which has been painted (other than factory <br /> applied) or damaged in any way. A stock of spare <br /> During installation,the following steps must be followed: sprinklers should be maintained to allow quick . <br /> replacement of damaged or operated sprinklers. Prior to <br /> 1. Cut the specified size hole (see illustrations) for the installation, sprinklers should be maintained in the original <br /> sprinkler in the ceiling or wall directly in line with the cartons and packaging until used to minimize the potential . <br /> tee. for damage to sprinklers that would cause improper <br /> 2. Apply pipe joint compound to the 1" (25mm) pipe operation or non operation. <br /> threads and install sprinkler using the Model G3 or <br /> G3 R/C Sprinkler Wrench as specified. *Spears CPVC sprinkler adapter tees(with steel thread <br /> 3. Install the Model FP push-on/thread-off escutcheon or insert) can only be used with horizontal sidewall <br /> CCP cover plate if required. sprinklers which do not require protrusion into tees to <br /> is not rec- prevent ice or debris blockage of sprinkler inlets. These <br /> Note: Installation of the Model F3QR Sprinklers <br /> CPVC tees do not permit sufficient sprinkler inlet <br /> ommended in copper pipe systems, as this may reduce protrusion as required for pendent installation. <br /> the life expectancy of the sprinklers. <br /> • <br /> Model F3QR Concealed and Recessed <br /> Installation Instructions • <br /> • The Model G3 R/C wrench(Fig. 1)is designed to locate <br /> on the wrenching pads of the recessed sprinkler while <br /> centering in the cup. A standard 1/2" drive ratchet may <br /> be used to drive this wrench. Figures 1 and 2 show • <br /> sequentially the insertion of the wrench.First the wrench, <br /> with its jaws above the sprinkler deflector, is moved • <br /> laterally until centered with the cup. Then raise the • <br /> wrench inside of the cup until its jaws engage the <br /> sprinkler's square wrenching pads (Fig. 3). To remove <br /> the wrench,follow this procedure in reverse order. Care <br /> should be taken to avoid striking the deflector, with the <br /> wrench. <br /> • <br /> 5. <br />
The URL can be used to link to this page
Your browser does not support the video tag.