G.EXITING REQUIREMENTS <br /> [Table 1003.2 3] <br /> OCCUPANCY F-1 <br /> OCC. REQ'D ACTUAL REQ'D ACTUAL <br /> AREA LOAD EXIT WIDTH* EXIT WIDTH STAIR WIDTH** STAIR WIDTH <br /> (inches per occupant=0.15) (inches per occupant=0.2) <br /> Ground Floor-North 1 42 6.30 72 8.40 N/A <br /> Ground Floor-North 2 29 4.35 36 5.80 N/A <br /> Ground Floor-North 3 358 53.70 68 71.60 N/A <br /> Ground Floor-South 1 41 6.15 36 8.20 N/A <br /> Ground Floor-South 2 54 8.10 36 10.80 N/A <br /> Ground Floor-South 3 203 30.45 36 40.60 48 <br /> First Floor-West Entry 194 29.10 72 38.80 N/A <br /> First Floor-South 1 1 0.15 36 0.20 N/A <br /> First Floor-South 2 38 5.70 64 7.60 N/A <br /> First Floor-South 3 61 9.15 72 12.20 N/A <br /> First Floor-South 4 116 17.40 36 23.20 N/A <br /> First Floor-North 194 29.10 72 38.80 48 <br /> Sub-basement 6 0.90 36 1.20 N/A <br /> * Door width shall not be less than 32 inches clear [Section 1003.3.1.1] <br /> ** Stairway width shall not be less than 44 inches [Section 1003.3.3] <br /> EXIT ACCESS TRAVEL DISTANCE: [Table 1004.2.4] <br /> OCCUPANCY ALLOWABLE* ACTUAL MAX. <br /> A,M 250 feet 210 feet <br /> B 300 feet 120 feet <br /> S-2 300 feet 185 feet <br /> *with sprinkler system <br /> H. PLUMBING SYSTEMS <br /> [Table 2902.1] <br /> MINIMUM NUMBER OF PLUMBING FACILITIES <br /> Occupancy Type No.of Occupants Water Closets/Urinals Lavatories Drinking Fountains Other <br /> Req'd Actual Req'd Actual Req'd Actual Req'd Actual <br /> Restaurant-First 838 6 male 7 male 2 male 3 male 2 1 1 service 1 service <br /> Floor 6 female 7 female 2 female 5 female sink sink <br /> Business-Second 1 male 1 male 1 service 0 service <br /> Floor 26 1 female 1 uni-sex* 1 female 1 uni sex 1 0*' sink sink <br /> Storage-Ground <br /> 2 male 6 m le 2 male 8 male 1 service 2 service <br /> Floor&Sub 283 2 female 7 fe le 2 female 6 female 1 1 sink sinks <br /> basement <br /> Imeiy- 1.12vil &e.ce,e-5.119(e, <br />