Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
t <br />.1 innetonka <br />waters edge <br />11 lj J <br />O \ <br />.0 <br />basement {loon 941 <br />/ r <br />IApprox. Jocattm Existing we// location fc be abandoned) <br />l of proposed / % g <br />wdJ -- / <br />9 <br />A9 " <br />c esr house = 3 . _ — <br />l to \\ ' \ \ _ _ _� d - 3f3 in, Ch ,b1a 947 <br />a <br />i r c k / exlsthy otic ,roFy� ' /I \\• \ \' <br />E.r'istirg Sept/c Ton de f <br /></ � <br />1500 goJJon pec ct�sf -_ <br />sotk tanks—Pine Tree <br />150d, gallon pump tank �. <br />,e Bed <br />v S� 9 Qy ocK <br />h Bed ` \ /�� S6' 3 ` Sp, 6 <br />s Rock <br />too <br />- g' <br />l- <br />C <br />y, <br />sst—bock <br />38 inch Oak- w <br />`i edge of wet ✓and <br />JIL N) <br />I <br />k A <br />ALd <br />' IrY e t L a /7 d ,1 <br />►lir_ '�'` '�- � � <br />AL <br />Ufa. ' <br />Ii <br />I <br />AL <br />silrf� <br />�-water's edge <br />~`\ - Minnetonka <br />Lake <br />/ <br />Septic System Site P/4717 <br />Pf?OPER IT Y L OCA TION <br />L o t 3, 8/oek 1, f UL LEl? TON TSTA Tf-5 <br />CITY- F" ()Rol% <br />SUILDIN E 1 <br />INSPECTOR <br />DATE � 2 � PERMIT NO. _ <br />APPROVED AS SUBMTTED <br />❑ APPROVED WITH CORRECTIONS AS NOTED <br />O NOT APPROVED--- CORRECT & RESUBMIT <br />These comments are for your information. All work shall be dons= <br />in ILII compliance with all applicable building and zoning Cods, - <br />Requirements including items not specifically noted in this review. <br />KEEP THIS PLAN SET ON SITE AT- ALL. TWU <br />LEGE1W <br />sor7 boring <br />percolation test hole <br />property existing elevation contour <br />8oun dory by others <br />_._ proposed elevation contour <br />*4 <br />exr�" ling spc t ere vvtro r-,�-�—- -<"ir_ '••r <br />g2xj proposed spot e%vatian <br />Elevations relative and assumed <br />Elevations relat/ve to U.5: G. S. 1929 N: G. V.D. <br />LN <br />Nal es. <br />1. Avoid compaction of mound areo before, duri,7g and <br />after construction <br />2 Verlfy before drll✓ing that no septic tanks or septic oreas <br />are within a 5o foot radius of proposed weal location. <br />(100 feet for shallow we//) <br />3. Verify before construction that no shallow we#s are within <br />100 feet, or deep wells within .50 feet of proposed septic <br />tanks or mound area. <br />4. :Strip all vegetative cover from mound area then prow or disk <br />surface. Oo not roto tl/ll /f trees ore present cut trunks at <br />ground level, Do not uproot! <br />5 To extend the life of septic system pump septic tanks a <br />minimum of every 2 years. <br />6: see attached sheets for additional construction detolls <br />7 Site plan prepared by or ander the supervJ•s/on of Tony <br />E✓lestad - M. ✓''. C.A. Certification No. 1410 <br />GRAPHIC SCALE <br />40 G 20 4c 80 <br />( IN FEET ) <br />1 inch = 40 ft. <br />,60 <br />h�BQUP.Sted by <br />IleS tGd <br />200 Cert tial A venue <br />Gn d <br />Bu ffG10; YA/ 55JI J <br />e/' vices <br />Phone 682--9,.329 <br />Fax 682--9002 <br />Alternate septic site 9--3--98 <br />Book 28 Rage 5 <br />Rev✓siors <br />Orawr, by. RKR <br />Date.• <br />0.6-17-98 <br />✓ab No. 9835 <br />