Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
gv „At <br /> CITY OF ORONO O <br /> Municipal Offices fo O <br /> Post Office Box 66 '- p. <br /> Crystal Bay, MN 55323-0066 ar ON—SITE SEWAGE TREATMENT <br /> 14 \ '.1)rl,1�' ' �4 INSPECTION REPORT <br /> k'EsHo <br /> Owner: ,Ad i< 1- ed Address: 47 .40-s-J1 J4'r1 IG.t <br /> Permit #'s: yloiY_ Dates:_ Contractors: Znk <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is 94 an existing system [ ] new construction) <br /> SYSTEM CONFORMITY (1-3): 3 <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any system with less than 3 fee of unsaturated soil or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The limiting soil characteristic [ .has or [ ] has not been identified at this time. If the limiting soil <br /> characteristic has not been identified, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): <br /> Tic inspection indicates: <br /> ( ) Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. <br /> 7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each <br /> tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). <br /> If tanks have not been pumped out within the last three years, they should be pumped out now. <br /> DRAINFIELD CONDITION (11-14): 'a <br /> Drainfield inspection indicates: <br /> 1L, Drainfield is dry, no surfacing evident. <br /> Q� •.11,_ evidence of surfacin• not cri ' e <br /> 13 Drain - . - ' - -• a • vtsl. y •isc arging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> hir— <br /> LIMITING SITE FACTORS (slope,setbacks,etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): 171-f% <br /> C. ENTS: A�fl - . /41„, "t / A i 6 <•� — id., ,Nr%iI a # JIM i '!A' 1 i <br /> - .<ar- '. S ,a--1_' <br /> Ararwire <br /> Da e of Inspection ep c Sys em Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly, but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> information. <br /> This report must be kept on the premises with the system location and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />